# Rack PDU APC NetShelter Switched 0U 5.0 kW 200/208V 30A 21xC13/C15 + 3xC19/C21

**URL:** https://aio.lv/en/product--apc-apdu9941--12005433
**Data updated:** 2026-03-11 20:40 (EET)
**Category:** PDU
**Manufacturer:** APC
**Manufacturer code:** APDU9941
**EAN:** 0731304356264
**Warranty:** 2 Years
**Availability:** Available for order
**Price:** 1 747.49 €
**Prices and availability valid until:** 2026-07-12 23:59
**Price without VAT (21%):** 1 444.21 EUR
**Can be purchased by legal entities:** Yes (invoice)
**Buy:** https://aio.lv/en/product--apc-apdu9941--12005433

## Delivery options

| Delivery method | Delivery time | Cost |
|---|---|---|
| Office pickup (2b. Kengaraga str., Riga, Latvia, LV-1063) | 30.06.2026 | free |
| Pickup points | 03.07.2026 | 1.99 EUR |
| Courier delivery to door | 03.07.2026 | 7.44 EUR |

## Summary description

Switched rack PDU for data centre and IT cabinets, APC NetShelter model with 0U mounting and single-phase operation. Delivers up to 5.0 kW at 200–208 V with 30 A input (NEMA L6-30P). Provides 24 AC outlets: 21 C13/C15 and 3 C19/C21. Supports remote switching and power distribution, complies with RoHS, CUL, FCC and PSE standards. Dimensions: 55×46×1829 mm.

## Long description

APC NetShelter Switched 0U Rack PDU delivers controlled power distribution for data centres and IT cabinets. This 0U, single‑phase PDU supports up to 5.0 kW at 200–208 V with a 30 A input (NEMA L6‑30P) and provides 24 AC outlets: 21 hybrid C13/C15 outlets and 3 hybrid C19/C21 outlets. The unit includes a Network Management Card for remote monitoring and control, an interactive LCD for local measurements, a temperature/humidity sensor port and a USB port for local firmware updates. With compact 0U mounting and dimensions of 55×46×1829 mm, the PDU installs vertically without occupying usable rack units.
Advantages
The switched design enables outlet‑level on/off control and remote switching for power cycling, delayed power sequencing and outlet use management. Hybrid outlets accept standard C14/C20 cords and are rated to support higher temperature power cords, allowing compatibility with present and future server and network equipment. Integrated network management and secure interfaces support Web, SNMP and CLI access and simplify centralized monitoring and control. The PDU supports daisy‑chaining up to 32 units on a single IP address to reduce network complexity.
Suitable for
 Rack power distribution in server rooms and data centres
 Remote power cycling and management of individual servers and network devices
 Environments requiring high‑density outlet provisioning and vertical 0U mounting
 Integrations with monitoring platforms such as EcoStruxure IT
Key specifications
 Output power capacity: up to 5.0 kW at 200–208 V
 Input current: 30 A via NEMA L6‑30P plug (single‑phase)
 Outlet count and types: 21 hybrid IEC 60320 C13/C15 and 3 hybrid IEC 60320 C19/C21
 Mounting: 0U vertical rack installation; dimensions 55×46×1829 mm
 Network management: onboard Network Management Card with Web, SNMP and CLI access
 Local interface: color interactive LCD showing current, real power, voltage and energy
 Sensors and ports: temperature/humidity sensor port and USB port for firmware updates
 Security and standards: supports enhanced password policies and compliance with RoHS, CUL, FCC and PSE
 Additional features: outlet locking when using locking cords, low‑profile circuit breakers, daisy‑chain up to 32 PDUs
How to use
Install the PDU vertically in a compatible rack using available 0U mounting points; connect the NEMA L6‑30P input plug to a properly rated branch circuit. Configure the Network Management Card via the Web interface, SNMP or CLI to assign IP addressing and security credentials. Use the color LCD for local measurements and status checks. Control individual outlets from the management interface for remote power on/off, sequencing or scheduled operations. Attach the temperature/humidity sensor where environmental monitoring is required and update firmware via the USB port as needed.
Usage recommendations
Verify rack airflow and device thermal ratings when populating high‑temperature equipment. Use compatible IEC power cords and locking cords where outlet locking is required. When daisy‑chaining multiple PDUs, plan IP addressing and network security settings to maintain visibility and control. Follow local electrical codes and work with qualified electricians for installation and service.

## Specifications

### Design

| Feature | Value |
|---|---|
| PDU types | Switched |
| Type | Single-phase |
| Product colour | Black |
| Mounting | Vertical |
| Rack capacity | 0U |

### Power

| Feature | Value |
|---|---|
| Nominal input voltage | 90 - 264 |
| Maximum current | 30 A |
| Nominal output voltage | 200 - 208 |
| Load capacity | 4992 VA |

### Ports & interfaces

| Feature | Value |
|---|---|
| AC outlets quantity | 24 AC outlet(s) |
| Ethernet LAN (RJ-45) ports | 1 |
| Power plug | NEMA L6-30P |
| AC outlet types | C13 coupler, C15 coupler, C19 coupler, C21 coupler |

### Weight & dimensions

| Feature | Value |
|---|---|
| Weight | 8.5 kg |
| Height | 1829 mm |
| Width | 55 mm |
| Depth | 46 mm |

### Operational conditions

| Feature | Value |
|---|---|
| Operating altitude | 0 - 3048 |
| Operating relative humidity (H-H) | 5 - 95 |
| Storage temperature (T-T) | -25 - 65 |
| Operating temperature (T-T) | -5 - 60 |
| Non-operating altitude | 0 - 15240 |

### Packaging content

| Feature | Value |
|---|---|
| Manual | Yes |

### Certificates

| Feature | Value |
|---|---|
| Certification | CUL , FCC 15 A, ICES-003, PSE |
| Compliance certificates | RoHS |

### Packaging data

| Feature | Value |
|---|---|
| Package weight | 10000 g |
| Package depth | 124 mm |
| Package height | 2040 mm |
| Package width | 165 mm |

### Sustainability

| Feature | Value |
|---|---|
| Sustainability compliance | Yes |

## FAQ

### How much does the APC NetShelter Switched Rack PDU 0U 5.0 kW cost, and is it available for purchase?

The price is 1,747.49 € (valid at the time of publication and already includes all taxes). The item is available for order — 6 pcs. are in stock, and you can place your purchase right now with delivery across Latvia and Europe or choose pickup at the Riga collection point. We offer favorable purchase terms, including the option to split the payment into convenient monthly installments. Availability and price are updated in real time, so we recommend placing your order in advance.

### If I order this product today, when will I receive my order?

If you place your order today, delivery will be as fast and convenient as possible. You will be able to pick up your order on 30.06.2026 at the Riga pickup point or choose delivery across Latvia and Europe. We carefully inspect every purchase and pack it securely for safe transportation.

### What payment options are available?

AiO.lv offers several payment methods: Cash payment, Bank transfer, Bank cards on-line, Apple Pay, Google Pay, Leasing for legal entities. All transactions are 100% secure and encrypted.

### Can this product be purchased for a company (with VAT)?

Yes. AiO.lv works with legal entities in Latvia and across Europe. The product price already includes VAT. For certain product categories, as well as for companies from other EU countries with a valid VAT number, a 0% VAT rate may apply. We issue the invoice immediately after the order is placed, support electronic BIS invoices, and automatically generate all necessary accounting documents. You can complete the purchase for a company online — simply select the company profile and choose bank transfer as the payment method during checkout.

### What is the warranty period?

All APC products come with an official 2 Years warranty. It covers all manufacturing defects and malfunctions that may occur during use. The warranty is valid at all authorized APC service centers and through AiO.lv

### Can the product be returned after purchase?

Yes, you can return the product within 14 days of purchase if you bought it as a consumer (not a legal entity). Returns are possible without giving any reason — the main condition is that the product retains its original appearance and full set of accessories. We will make the process as simple and convenient as possible: just contact our customer support team, and we will help you arrange the return.

### Where should I contact for warranty service?

For warranty-related questions you can contact the AiO.lv (SIA VSPRO) customer support team. More information about warranty service: https://aio.lv/en/warranty

### How can I tell if this product suits my needs?

When making a choice, we recommend paying attention to the key features: nominal input voltage, maximum current, ac outlets quantity, weight, pdu types, product colour, compatibility with your devices or usage conditions, material quality, functionality, and warranty terms. These characteristics will help you determine how well the model meets your needs.

### Where can I download the instructions for APC NetShelter Switched Rack PDU 0U 5.0 kW?

You can download the instructions in PDF format from the “Instructions” section on the product description page. The file contains complete information about installation, setup, and usage.

## Image

https://aio.lv/img/cache/product/12005433/67463577_large.webp