## Summary description

ETI EFI-P2 AC 16/0.03 is a type AC residual current device (RCD) designed to detect and disconnect alternating residual currents. Rated for 16 A nominal current and 30 mA residual sensitivity, it provides protection against electric shock and earth leakage in residential and light-commercial installations. Suitable for use on AC-only circuits to improve electrical safety and comply with wiring regulations.

## Long description

The ETI EFI-P2 AC 16/0.03 is a residual current device (RCD) designed to detect alternating residual currents and disconnect the circuit when leakage exceeds the rated sensitivity. With a nominal current rating of 16 A and a trip sensitivity of 30 mA, this type AC RCD is intended for AC-only circuits in residential and light-commercial electrical installations to reduce the risk of electric shock and limit earth leakage faults.
Advantages
This RCD offers fast disconnection for AC-type residual currents with a compact DIN-rail housing that fits standard distribution boards. Its 16 A rating makes it suitable for individual circuits or small groups of loads, while the 30 mA sensitivity provides protected operation for persons and helps meet common electrical safety requirements. The design is focused on reliable detection of sinusoidal AC leakage currents and simple integration into existing installations.
Suitable for
 Protection of lighting and socket circuits in homes
 Individual small appliance circuits and branch circuits
 Light-commercial installations where only AC residual currents are expected
 Retrofit into existing DIN-rail distribution panels
When it may not be suitable
This type AC RCD detects and trips on alternating (sinusoidal) residual currents only. It is not suitable where pulsating DC or smooth DC residual currents may occur, such as circuits with certain electronic equipment, variable-speed drives, photovoltaic inverters, or EV chargers; in those cases a type A or type B device is required. Also, the 16 A nominal current rating limits its use to single circuits or small groups rather than high-current feeders.
Key specifications
 Device type: Type AC residual current device (RCD)
 Rated residual operating current (sensitivity): 30 mA
 Rated current: 16 A
 Function: Detects and disconnects on AC residual currents
 Mounting: DIN-rail compatible enclosure for distribution boards
 Application: Residential and light-commercial AC-only circuits
How to use
Install the RCD in the distribution board on a standard DIN rail according to local wiring regulations. Ensure supply and load conductors are connected to the correct terminals and that the device is placed upstream of the circuits requiring protection. After wiring, test the device using the built-in test button to verify trip operation. Routine testing at recommended intervals is required to confirm continued functionality.
What to consider before purchase
 Verify that the protected circuits only produce AC residual currents (no DC components)
 Confirm the 16 A rated current is adequate for the intended circuit load
 Ensure there is space on the DIN rail in the distribution board for installation
 Check local electrical codes for required RCD type and sensitivity for specific applications
Usage recommendations
Use the ETI EFI-P2 AC 16/0.03 on individual lighting or socket circuits and perform the manual test monthly. For circuits with electronic equipment or potential DC leakage, select a device with appropriate type designation (A or B) instead.

## Specifications

### Weight & dimensions

| Feature | Value |
|---|---|
| Weight | 0.187 kg |

## FAQ

### How much does the ETI EFI-P2 AC 16/0.03 RCD cost, and is it available for purchase?

The price is 31.99 € (valid at the time of publication and already includes all taxes). The item is available for order — 52 pcs. are in stock, and you can place your purchase right now with delivery across Latvia and Europe or choose pickup at the Riga collection point. We offer favorable purchase terms, including the option to split the payment into convenient monthly installments. Availability and price are updated in real time, so we recommend placing your order in advance.

### If I order this product today, when will I receive my order?

If you place your order today, delivery will be as fast and convenient as possible. You will be able to pick up your order on Thursday at the Riga pickup point or choose delivery across Latvia and Europe. We carefully inspect every purchase and pack it securely for safe transportation.

### What payment options are available?

AiO.lv offers several payment methods: Bank transfer, Bank cards on-line, Apple Pay, Google Pay. All transactions are 100% secure and encrypted.

### Can this product be purchased for a company (with VAT)?

Yes. AiO.lv works with legal entities in Latvia and across Europe. The product price already includes VAT. For certain product categories, as well as for companies from other EU countries with a valid VAT number, a 0% VAT rate may apply. We issue the invoice immediately after the order is placed, support electronic BIS invoices, and automatically generate all necessary accounting documents. You can complete the purchase for a company online — simply select the company profile and choose bank transfer as the payment method during checkout.

### What is the warranty period?

All ETI products come with an official 2 Years warranty. It covers all manufacturing defects and malfunctions that may occur during use. The warranty is valid at all authorized ETI service centers and through AiO.lv

### Can the product be returned after purchase?

Yes, you can return the product within 14 days of purchase if you bought it as a consumer (not a legal entity). Returns are possible without giving any reason — the main condition is that the product retains its original appearance and full set of accessories. We will make the process as simple and convenient as possible: just contact our customer support team, and we will help you arrange the return.

### Where should I contact for warranty service?

For warranty-related questions you can contact the AiO.lv (SIA VSPRO) customer support team. More information about warranty service: https://aio.lv/en/warranty

### How can I tell if this product suits my needs?

When making a choice, we recommend paying attention to the key features: weight, compatibility with your devices or usage conditions, material quality, functionality, and warranty terms. These characteristics will help you determine how well the model meets your needs.

## Image

https://aio.lv/img/cache/product/4909661/30584851_large.webp