# Circuit Breaker 3P ETI C-13AE 6 kA C characteristic, 3-pole

**URL:** https://aio.lv/en/product--eti-002145515--10833595
**Data updated:** 2026-04-27 22:26 (EEST)
**Category:** Power Sockets
**Manufacturer:** ETI
**Manufacturer code:** 002145515
**EAN:** 5904722947801
**Warranty:** 2 Years
**Availability:** Available for order
**Price:** 12.49 €
**Prices and availability valid until:** 2026-07-16 23:59
**Price without VAT (21%):** 10.32 EUR
**Can be purchased by legal entities:** Yes (invoice)
**Buy:** https://aio.lv/en/product--eti-002145515--10833595

## Delivery options

| Delivery method | Delivery time | Cost |
|---|---|---|
| Office pickup (2b. Kengaraga str., Riga, Latvia, LV-1063) | 22.06.2026 | free |
| Pickup points | 29.06.2026 | 1.99 EUR |
| Courier delivery to door | 29.06.2026 | 4.99 EUR |

## Summary description

Three-pole ETI circuit breaker model C-13AE with C tripping characteristic and 6 kA short-circuit breaking capacity. Designed for protection of three-phase circuits against overloads and short circuits, suitable for residential and light commercial distribution boards. Provides reliable thermal-magnetic protection and selectable mounting in standard DIN-rail systems.

## Long description

The ETI Circuit Breaker 3P C-13AE is a three-pole thermal-magnetic protective device with a C tripping characteristic and a rated short-circuit breaking capacity of 6 kA. Intended for three-phase circuits in residential and light commercial electrical distribution systems, it combines overload and short-circuit protection in a single compact module. The breaker is compatible with standard DIN-rail mounting and provides selective tripping behavior suitable for typical inductive and resistive loads.
Advantages
This three-pole breaker offers coordinated thermal-magnetic protection across all phases, helping to limit damage from overloads and short circuits. The C characteristic gives a balanced response for general-purpose circuits with moderate inrush currents such as motors and fluorescent lighting. With a 6 kA breaking capacity, the device can interrupt common fault currents found in small to medium installations while fitting standard DIN-rail distribution boards for straightforward installation.
Suitable for
 Protection of three-phase circuits in residential distribution boards
 Light commercial and office electrical panels
 Circuits with moderate inrush currents—small motors, HVAC starters, lighting
 Retrofit or new installations using standard DIN-rail systems
When it may not be suitable
This breaker is not intended for high-energy industrial sites where fault levels exceed 6 kA or where selective coordination with upstream devices requires higher breaking capacities. It may also be unsuitable for circuits with very high motor starting currents or specialized protection needs (such as earth-leakage sensing) that demand other device types.
Key specifications
 Poles: 3-pole configuration for three-phase protection
 Tripping characteristic: C type (moderate magnetic trip threshold)
 Short-circuit breaking capacity: 6 kA
 Protection method: thermal-magnetic (combined overload and short-circuit)
 Mounting: standard DIN-rail compatible
How to use
Install the breaker on a compatible DIN-rail inside the distribution board, ensuring correct orientation and secure mechanical fixing. Connect the three phase conductors to the input terminals and the outgoing load conductors to the output terminals according to the panel wiring diagram. Verify that the system voltage and current rating of the selected breaker size match the circuit requirements and that upstream protection and coordination are adequate. After wiring, perform insulation and continuity checks and test the breaker operation under no-load conditions before placing the circuit into service.
What to consider before purchase
 Match the breaker rated current to the circuit load and expected continuous current
 Confirm that a C characteristic is appropriate for the load type and inrush behavior
 Verify that a 6 kA breaking capacity meets the installation fault level and coordination needs
 Ensure physical compatibility with the distribution board DIN-rail and terminal space
Usage recommendations
For reliable protection, select the breaker rated current to exceed expected continuous load with appropriate margin, coordinate with upstream devices to ensure selective tripping where required, and follow local electrical codes and installation practices. Periodically inspect connections for tightness and signs of overheating, and replace the device if it shows signs of mechanical or electrical damage.

## FAQ

### How much does the Circuit Breaker 3P ETI C-13AE cost, and is it available for purchase?

The price is 12.49 € (valid at the time of publication and already includes all taxes). The item is available for order — 24 pcs. are in stock, and you can place your purchase right now with delivery across Latvia and Europe or choose pickup at the Riga collection point. We offer favorable purchase terms, including the option to split the payment into convenient monthly installments. Availability and price are updated in real time, so we recommend placing your order in advance.

### If I order this product today, when will I receive my order?

If you place your order today, delivery will be as fast and convenient as possible. You will be able to pick up your order on 22.06.2026 at the Riga pickup point or choose delivery across Latvia and Europe. We carefully inspect every purchase and pack it securely for safe transportation.

### What payment options are available?

AiO.lv offers several payment methods: Bank transfer, Bank cards on-line, Apple Pay, Google Pay. All transactions are 100% secure and encrypted.

### Can this product be purchased for a company (with VAT)?

Yes. AiO.lv works with legal entities in Latvia and across Europe. The product price already includes VAT. For certain product categories, as well as for companies from other EU countries with a valid VAT number, a 0% VAT rate may apply. We issue the invoice immediately after the order is placed, support electronic BIS invoices, and automatically generate all necessary accounting documents. You can complete the purchase for a company online — simply select the company profile and choose bank transfer as the payment method during checkout.

### What is the warranty period?

All ETI products come with an official 2 Years warranty. It covers all manufacturing defects and malfunctions that may occur during use. The warranty is valid at all authorized ETI service centers and through AiO.lv

### Can the product be returned after purchase?

Yes, you can return the product within 14 days of purchase if you bought it as a consumer (not a legal entity). Returns are possible without giving any reason — the main condition is that the product retains its original appearance and full set of accessories. We will make the process as simple and convenient as possible: just contact our customer support team, and we will help you arrange the return.

### Where should I contact for warranty service?

For warranty-related questions you can contact the AiO.lv (SIA VSPRO) customer support team. More information about warranty service: https://aio.lv/en/warranty

## Image

https://aio.lv/img/cache/product/10833595/60168723_large.webp

