# Residual Current Device (RCD) Eti-Polam EFI-P2 A 2P 16A 30mA (002061110)

**URL:** https://aio.lv/en/product--eti-polam-002061110--12397375
**Data updated:** 2026-04-27 22:29 (EEST)
**Category:** Power Sockets
**Manufacturer:** Eti-Polam
**Manufacturer code:** 002061110
**EAN:** 3838895864226
**Warranty:** 2 Years
**Availability:** Available for order
**Price:** 40.99 €
**Prices and availability valid until:** 2026-07-25 23:59
**Price without VAT (21%):** 33.88 EUR
**Can be purchased by legal entities:** Yes (invoice)
**Buy:** https://aio.lv/en/product--eti-polam-002061110--12397375

## Delivery options

| Delivery method | Delivery time | Cost |
|---|---|---|
| Office pickup (2b. Kengaraga str., Riga, Latvia, LV-1063) | 16.07.2026 | free |
| Pickup points | 21.07.2026 | 1.89 EUR |
| Courier delivery to door | 21.07.2026 | 4.99 EUR |

## Summary description

Eti-Polam EFI-P2 A is a 2-pole residual current device (RCD) rated 16A with 30mA sensitivity for protection against earth leakage currents. Designed to detect and disconnect faults between live and neutral, it provides personal protection against electric shock and reduces fire risk. Suitable for residential and light commercial circuits requiring 2P 16A 0.03A protection.

## Long description

Eti-Polam EFI-P2 A 2P 16A 30mA is a two-pole residual current device (RCD) intended to detect earth leakage currents and disconnect the circuit when imbalance between live and neutral exceeds 30 mA. Designed for residential and light commercial electrical installations, this RCD provides personal protection against electric shock and contributes to fire prevention by cutting off fault currents quickly. The compact two-pole format supports single-phase circuits where protection of both poles is required.
Advantages
The device offers 30 mA sensitivity, which is a common threshold for personal protection, and a rated current of 16 A suitable for typical household or small commercial circuits. Its two-pole design isolates both live and neutral conductors simultaneously, improving safety during fault conditions. The construction is intended for DIN-rail mounting in distribution boards and compatible with standard wiring practices, allowing straightforward integration into existing installations.
Suitable for
 Residential single-phase circuits requiring 16 A protection
 Bathrooms, kitchens, and other areas where increased protection against electric shock is needed
 Light commercial or service outlets with low to moderate load requirements
 Supplementing circuit protection in distribution boards alongside overcurrent devices
When it may not be suitable
This RCD is not designed for three-phase TN or TT systems where more poles or different sensitivity classes may be required. It is also not a substitute for overload or short-circuit protection devices; proper coordination with circuit breakers or fuses is necessary. For circuits with loads exceeding 16 A or for specific medical, industrial, or safety-critical installations, a device with appropriate rated current, multiple poles or different characteristics should be selected.
Key specifications
 Number of poles: 2 (two-pole protection)
 Rated current: 16 A
 Residual current sensitivity: 30 mA (0.03 A)
 Type: AC or type A (detects AC and pulsating DC residual currents as indicated by product family)
 Intended mounting: DIN-rail in distribution boards
 Typical application: single-phase circuits (live and neutral protection)
How to use
Install the RCD in the consumer unit or distribution board on a standard DIN rail, ensuring correct orientation and secure terminal connections for line and neutral conductors. Before commissioning, verify correct wiring and test the device using its built-in test function or an external RCD tester to confirm operation at the specified 30 mA trip level. Coordinate with upstream overcurrent protection and follow local electrical regulations and wiring practices. After installation, periodically test the device to ensure continued operation.
What to consider before purchase
 Confirm the circuit rated current requirement does not exceed 16 A
 Check whether two-pole protection is appropriate for your single-phase installation
 Ensure compatibility with your distribution board mounting and terminal sizes
 Verify that 30 mA sensitivity meets local regulations and the level of personal protection needed
Usage recommendations
Use this RCD as part of a coordinated protection scheme: pair it with correctly rated overcurrent devices, install in accessible locations for regular testing, and follow national wiring regulations. Regular testing and professional installation are recommended to maintain effective residual current protection.

## FAQ

### How much does the RCD Eti-Polam EFI-P2 A 2P 16A 30mA cost, and is it available for purchase?

The price is 40.99 € (valid at the time of publication and already includes all taxes). The item is available for order — 14 pcs. are in stock, and you can place your purchase right now with delivery across Latvia and Europe or choose pickup at the Riga collection point. We offer favorable purchase terms, including the option to split the payment into convenient monthly installments. Availability and price are updated in real time, so we recommend placing your order in advance.

### If I order this product today, when will I receive my order?

If you place your order today, delivery will be as fast and convenient as possible. You will be able to pick up your order on 16.07.2026 at the Riga pickup point or choose delivery across Latvia and Europe. We carefully inspect every purchase and pack it securely for safe transportation.

### What payment options are available?

AiO.lv offers several payment methods: Bank transfer, Bank cards on-line, Apple Pay, Google Pay. All transactions are 100% secure and encrypted.

### Can this product be purchased for a company (with VAT)?

Yes. AiO.lv works with legal entities in Latvia and across Europe. The product price already includes VAT. For certain product categories, as well as for companies from other EU countries with a valid VAT number, a 0% VAT rate may apply. We issue the invoice immediately after the order is placed, support electronic BIS invoices, and automatically generate all necessary accounting documents. You can complete the purchase for a company online — simply select the company profile and choose bank transfer as the payment method during checkout.

### What is the warranty period?

All Eti-Polam products come with an official 2 Years warranty. It covers all manufacturing defects and malfunctions that may occur during use. The warranty is valid at all authorized Eti-Polam service centers and through AiO.lv

### Can the product be returned after purchase?

Yes, you can return the product within 14 days of purchase if you bought it as a consumer (not a legal entity). Returns are possible without giving any reason — the main condition is that the product retains its original appearance and full set of accessories. We will make the process as simple and convenient as possible: just contact our customer support team, and we will help you arrange the return.

### Where should I contact for warranty service?

For warranty-related questions you can contact the AiO.lv (SIA VSPRO) customer support team. More information about warranty service: https://aio.lv/en/warranty

## Image