# Electrical enclosure accessory Hager ADA906D, AC input 240 V

**URL:** https://aio.lv/en/product--hager-ada906d--12020816
**Data updated:** 2026-03-13 14:25 (EET)
**Category:** Power Sockets
**Manufacturer:** Hager
**Manufacturer code:** ADA906D
**EAN:** 3250611010616
**Warranty:** 2 Years
**Availability:** Out of stock

## Summary description

Hager ADA906D is an electrical enclosure accessory designed for integration into distribution boards and control cabinets. It accepts AC input voltage of 240 V and is intended to support installation and connection tasks within electrical enclosures. Suitable for use in residential and light commercial electrical systems where a compatible Hager accessory is required.

## Long description

Hager ADA906D 1+N residual-current circuit breaker combines earth-leakage detection with overcurrent protection in a single compact device. Rated for 6 A with a B-type tripping curve and 30 mA residual current sensitivity (Type A), this RCBO is designed for installation in residential and light-commercial distribution boards to protect sockets, lighting circuits and connected appliances from leakage currents, short circuits and overloads.
Advantages
The unit integrates residual-current and short-circuit/overload protection, reducing the number of separate devices required in a distribution board and simplifying wiring. A 1+N pole design allows neutral disconnection together with the phase, and the B-characteristic provides reliable tripping for circuits with low inrush currents such as general lighting and household sockets. Sensitivity to 30 mA residual current offers personal protection against indirect contact while permitting correct operation with AC and pulsating DC fault currents typical for modern appliances.
Suitable for
Protection of household socket circuits and small appliance outlets
Lighting circuits in homes, apartments and small commercial spaces
Branch circuits supplying washing machines, dishwashers and similar domestic appliances
Key specifications
Poles: 1+N (phase and neutral switching)
Rated current: 6 A
Tripping curve: B-characteristic (suitable for low inrush loads)
Residual current sensitivity: 30 mA, Type A (detects AC and pulsating DC leakage)
Combined functions: earth-leakage detection plus overcurrent protection (RCBO)
How to use
Install the RCBO in a compatible DIN-rail distribution board according to local wiring regulations and manufacturer installation instructions. Connect the phase conductor to the designated phase terminal and the neutral conductor to the neutral terminal so the device interrupts both poles. Ensure correct upstream coordination with main protective devices and verify the rated current and characteristic match the protected circuit. After wiring, test the residual-current trip function using a suitable test button or test device and perform standard commissioning checks before energizing connected loads.
Usage recommendations
Use this device for circuits where combined leakage and overload protection is required. Avoid installing in environments with significant dust, moisture or corrosive atmospheres without appropriate enclosure protection, and coordinate with upstream protection for selectivity. Periodically test the residual-current function to verify continued protection.

## Specifications

| Feature | Value |
|---|---|
| Quantity | 1 |
| AC input voltage | 240 V |
| Compliance certificates | RoHS |

## FAQ

### What payment options are available?

AiO.lv offers several payment methods: Bank transfer. All transactions are 100% secure and encrypted.

### Can this product be purchased for a company (with VAT)?

Yes. AiO.lv works with legal entities in Latvia and across Europe. The product price already includes VAT. For certain product categories, as well as for companies from other EU countries with a valid VAT number, a 0% VAT rate may apply. We issue the invoice immediately after the order is placed, support electronic BIS invoices, and automatically generate all necessary accounting documents. You can complete the purchase for a company online — simply select the company profile and choose bank transfer as the payment method during checkout.

### What is the warranty period?

All Hager products come with an official 2 Years warranty. It covers all manufacturing defects and malfunctions that may occur during use. The warranty is valid at all authorized Hager service centers and through AiO.lv

### Can the product be returned after purchase?

Yes, you can return the product within 14 days of purchase if you bought it as a consumer (not a legal entity). Returns are possible without giving any reason — the main condition is that the product retains its original appearance and full set of accessories. We will make the process as simple and convenient as possible: just contact our customer support team, and we will help you arrange the return.

### Where should I contact for warranty service?

For warranty-related questions you can contact the AiO.lv (SIA VSPRO) customer support team. More information about warranty service: https://aio.lv/en/warranty

## Image

https://aio.lv/img/cache/product/12020816/67616308_large.webp