# Hager ADZ313D RCBO Residual Current Circuit Breaker with Overcurrent Protection 1P+N 13A 30mA Type A 6kA

**URL:** https://aio.lv/en/product--hager-adz313d--12470768
**Data updated:** 2026-05-18 09:35 (EEST)
**Category:** Power Sockets
**Manufacturer:** Hager
**Manufacturer code:** ADZ313D
**EAN:** 3250611020141
**Warranty:** 2 Years
**Availability:** Available for order
**Price:** 125.99 €
**Prices and availability valid until:** 2026-08-02 23:59
**Price without VAT (21%):** 104.12 EUR
**Can be purchased by legal entities:** Yes (invoice)
**Buy:** https://aio.lv/en/product--hager-adz313d--12470768

## Delivery options

| Delivery method | Delivery time | Cost |
|---|---|---|
| Office pickup (2b. Kengaraga str., Riga, Latvia, LV-1063) | 22.07.2026 | free |
| Pickup points | 27.07.2026 | 1.89 EUR |
| Courier delivery to door | 27.07.2026 | 4.99 EUR |

## Summary description

The Hager ADZ313D is a high-quality RCBO designed for electrical circuit protection. This 1P+N device features a 13A rated current, 30mA sensitivity, and Type A protection, ensuring safety against both overcurrent and residual current faults. With a 6kA breaking capacity and 230V AC input, it is suitable for residential and commercial electrical installations requiring reliable fault detection and circuit isolation.

## Long description

The Hager ADZ313D is a professional-grade RCBO (Residual Current Circuit Breaker with Overcurrent Protection) engineered to provide comprehensive electrical safety in a single compact unit. Designed for 1P+N configurations, this device combines the functions of a miniature circuit breaker and a residual current device, effectively protecting circuits against both overcurrent conditions and hazardous leakage currents. With a rated current of 13A and a sensitivity of 30mA, it is an essential component for modern electrical distribution boards, ensuring reliable performance and enhanced safety for connected equipment and users.
Advantages
This device offers a significant space-saving advantage by integrating two protective functions into one module, which simplifies installation and reduces the footprint within the distribution cabinet. The Type A protection ensures that the unit can detect both AC and pulsating DC residual currents, providing a higher level of safety compared to standard AC-type devices. Its robust construction and 6kA breaking capacity allow it to handle electrical faults effectively, maintaining system integrity and preventing potential damage to wiring and appliances.
Suitable for
Residential electrical installations
Commercial office circuit protection
Protection of lighting and socket circuits
Systems requiring Type A residual current detection
When it may not be suitable
This RCBO is designed for 230V AC single-phase systems and is not suitable for three-phase industrial applications or circuits requiring higher current ratings than 13A. It should not be used in environments where the electrical load consistently exceeds its rated capacity or in specialized industrial processes that require different tripping characteristics.
Key specifications
Rated current: 13A
Residual current sensitivity: 30mA
Input voltage: 230V AC
Breaking capacity: 6kA
Protection type: Type A
Configuration: 1P+N
How to use
The Hager ADZ313D must be installed by a qualified electrician in accordance with local electrical regulations. It is designed for mounting on a standard DIN rail within a distribution board. Ensure that the supply cables are correctly connected to the input terminals and the load cables to the output terminals, observing the correct polarity for the phase and neutral conductors. Once installed, the device can be activated by moving the toggle switch to the 'ON' position. Regular testing using the integrated test button is recommended to verify the mechanical operation of the tripping mechanism.
What to consider before purchase
Verify that the 13A rating is appropriate for the specific circuit load
Ensure the distribution board has sufficient DIN rail space
Confirm that Type A protection meets the requirements of your connected appliances
Check that the 6kA breaking capacity is sufficient for the prospective short-circuit current of the installation
Usage recommendations
Regularly test the RCBO using the built-in test button at least every six months to ensure the residual current detection mechanism remains functional and responsive.

## Specifications

| Feature | Value |
|---|---|
| Quantity | 1 |
| AC input voltage | 230 |
| Compliance certificates | RoHS |

## FAQ

### How much does the Hager ADZ313D RCBO Circuit Breaker cost, and is it available for purchase?

The price is 125.99 € (valid at the time of publication and already includes all taxes). The item is available for order — 3 pcs. are in stock, and you can place your purchase right now with delivery across Latvia and Europe or choose pickup at the Riga collection point. We offer favorable purchase terms, including the option to split the payment into convenient monthly installments. Availability and price are updated in real time, so we recommend placing your order in advance.

### If I order this product today, when will I receive my order?

If you place your order today, delivery will be as fast and convenient as possible. You will be able to pick up your order on 22.07.2026 at the Riga pickup point or choose delivery across Latvia and Europe. We carefully inspect every purchase and pack it securely for safe transportation.

### What payment options are available?

AiO.lv offers several payment methods: Bank transfer, Bank cards on-line, Apple Pay, Google Pay, Installment. All transactions are 100% secure and encrypted.

### Can Hager ADZ313D RCBO Circuit Breaker be purchased with a lease?

Yes, the purchase is available both on credit and with an interest-free installment plan. Learn more about installments and credit options: https://aio.lv/en/payment#b3

### Can this product be purchased for a company (with VAT)?

Yes. AiO.lv works with legal entities in Latvia and across Europe. The product price already includes VAT. For certain product categories, as well as for companies from other EU countries with a valid VAT number, a 0% VAT rate may apply. We issue the invoice immediately after the order is placed, support electronic BIS invoices, and automatically generate all necessary accounting documents. You can complete the purchase for a company online — simply select the company profile and choose bank transfer as the payment method during checkout.

### What is the warranty period?

All Hager products come with an official 2 Years warranty. It covers all manufacturing defects and malfunctions that may occur during use. The warranty is valid at all authorized Hager service centers and through AiO.lv

### Can the product be returned after purchase?

Yes, you can return the product within 14 days of purchase if you bought it as a consumer (not a legal entity). Returns are possible without giving any reason — the main condition is that the product retains its original appearance and full set of accessories. We will make the process as simple and convenient as possible: just contact our customer support team, and we will help you arrange the return.

### Where should I contact for warranty service?

For warranty-related questions you can contact the AiO.lv (SIA VSPRO) customer support team. More information about warranty service: https://aio.lv/en/warranty

## Image

https://aio.lv/img/cache/product/12470768/68788883_large.webp