# Power distribution unit Rittal 7979.236 (Metered) 30 AC outlets C13/C19, 3 m cable, three-phase 400 V, 16 A

**URL:** https://aio.lv/en/product--rittal-7979236--12400581
**Data updated:** 2026-04-29 13:48 (EEST)
**Category:** PDU
**Manufacturer:** Rittal
**Manufacturer code:** 7979236
**EAN:** 4028177947764
**Warranty:** 2 Years
**Availability:** Available for order
**Price:** 1 047.49 €
**Prices and availability valid until:** 2026-07-14 23:59
**Price without VAT (21%):** 865.69 EUR
**Can be purchased by legal entities:** Yes (invoice)
**Buy:** https://aio.lv/en/product--rittal-7979236--12400581

## Delivery options

| Delivery method | Delivery time | Cost |
|---|---|---|
| Office pickup (2b. Kengaraga str., Riga, Latvia, LV-1063) | 01.07.2026 | free |
| Pickup points | 06.07.2026 | 1.99 EUR |
| Courier delivery to door | 06.07.2026 | 4.99 EUR |

## Summary description

Rittal 7979.236 is a metered three-phase PDU designed for rack power distribution with 30 AC outlets (C13 and C19). It supports 400 V nominal input, maximum 16 A and up to 11 000 W. Features include 3 m power cable, current and voltage monitoring and network management via HTTP/HTTPS, SNMP, Modbus/TCP, OPC‑UA and other protocols for remote monitoring and control.

## Long description

The Rittal 7979.236 Metered Power Distribution Unit (PDU) is a three-phase rack-mounted power distribution device designed for professional IT environments. It supplies 30 AC outlets in a mix of C13 and C19 sockets, supports a nominal input voltage of 400 V and a maximum current of 16 A, and delivers up to 11 000 W of power. The unit features integrated per-phase energy measurement, onboard current and voltage monitoring, a 3 m power cable, and network management capabilities via HTTP/HTTPS, SNMP, Modbus/TCP and OPC‑UA for remote monitoring and data collection.
Advantages
The metered design provides accurate energy measurement (±1% kWh) to relevant standards, enabling precise power planning and billing. Built-in network interfaces and support for common management protocols allow centralized monitoring and integration with existing infrastructure management systems. The PDU is designed for vertical mounting in rack zero-U space and includes tool-free fitting options for compatible Rittal racks. Phase colour coding, adjustable alarm thresholds, and an integrated real-time clock with battery buffering increase operational clarity and reliability.
Suitable for
Data center and server rack power distribution where per-phase metering is required
Network rooms and colocation facilities needing remote monitoring and SNMP/Modbus integration
Racks with mixed C13 and C19 power requirements for servers, switches and storage equipment
Environments that require vertical, zero‑U mounting to preserve rack space
When it may not be suitable
This PDU is designed for three-phase 400 V infrastructures and a maximum current of 16 A; it is not suitable for single-phase installations or for systems requiring higher current capacities. It also does not replace a PDU with switched outlet control if per-outlet remote switching is required rather than metering and monitoring.
Key specifications
Input voltage: 400 V nominal
Maximum current: 16 A
Max. power capacity: up to 11 000 W
Outlets: 30 AC outlets (combination of C13 and C19)
Cable length: 3 m integrated power cable
Measurement accuracy: ±1% (kWh) to EN 62053-21
Mounting: vertical, zero-U rack mounting compatible with Rittal racks
Weight: 5.2 kg
Colour: Black
Monitoring interfaces: HTTP/HTTPS, SNMP, Modbus/TCP, OPC‑UA
How to use
Install the PDU vertically in the rack’s zero-U space or a compatible mounting position according to the rack manufacturer’s instructions. Connect the integrated 3 m power cable to the appropriate three-phase 400 V supply rated for up to 16 A. Use the built-in web interface or supported network protocols to configure monitoring, set warning and alarm thresholds for voltage, current and power, and to integrate with building management or monitoring systems. Regularly review measured values, operating hours and alarm logs to ensure balanced phase loading and to identify potential issues.
What to consider before purchase
Confirm your facility provides a three-phase 400 V supply and a circuit rated for 16 A
Ensure your rack supports vertical zero‑U mounting and that the unit’s dimensions and weight are compatible
Determine whether you need per-outlet switching (this unit is metered but not a switched PDU)
Plan network connectivity and protocol support required for your monitoring system (HTTP/HTTPS, SNMP, Modbus/TCP, OPC‑UA)
Usage recommendations
Balance loads across phases, set appropriate warning and alarm thresholds for current and power, and integrate the PDU into your monitoring system to make use of per-phase metering data for capacity planning and preventive maintenance.

## Specifications

### Design

| Feature | Value |
|---|---|
| PDU types | Metered |
| Type | Three-phase |
| Product colour | Black |
| Mounting | Vertical |
| Display | TFT |
| Rack capacity | 0U |
| Housing material | Plastic, Aluminium |

### Power

| Feature | Value |
|---|---|
| Nominal input voltage | 400 |
| Maximum current | 16 A |
| Maximum power | 11000 W |

### Ports & interfaces

| Feature | Value |
|---|---|
| AC outlets quantity | 30 AC outlet(s) |
| Serial ports quantity | 1 |
| Ethernet LAN (RJ-45) ports | 1 |
| AC outlet types | C13 coupler, C19 coupler |
| USB ports quantity | 1 |

### Weight & dimensions

| Feature | Value |
|---|---|
| Weight | 5.2 kg |
| Size (imperial) | 19 " |
| Height | 1495 mm |
| Width | 44 mm |
| Depth | 70 mm |

### Operational conditions

| Feature | Value |
|---|---|
| Operating relative humidity (H-H) | 10 - 95 |
| Storage temperature (T-T) | -20 - 70 |
| Operating temperature (T-T) | 5 - 50 |

### Management features

| Feature | Value |
|---|---|
| Supported network protocols | HTTP, HTTPS, SSL, SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP, Modbus/TCP, OPC-UA, MIB, FTP/SFTP |
| Firmware upgradeable | Yes |
| Monitoring | Voltage, Current |

### Features

| Feature | Value |
|---|---|
| Cable length | 3 m |
| LED indicators | Y |

## FAQ

### How much does the Rittal 7979.236 PDU Metered 30 outlets cost, and is it available for purchase?

The price is 1,047.49 € (valid at the time of publication and already includes all taxes). The item is available for order — 2 pcs. are in stock, and you can place your purchase right now with delivery across Latvia and Europe or choose pickup at the Riga collection point. We offer favorable purchase terms, including the option to split the payment into convenient monthly installments. Availability and price are updated in real time, so we recommend placing your order in advance.

### If I order this product today, when will I receive my order?

If you place your order today, delivery will be as fast and convenient as possible. You will be able to pick up your order on 01.07.2026 at the Riga pickup point or choose delivery across Latvia and Europe. We carefully inspect every purchase and pack it securely for safe transportation.

### What payment options are available?

AiO.lv offers several payment methods: Bank transfer, Bank cards on-line, Apple Pay, Google Pay, Installment, Leasing for legal entities. All transactions are 100% secure and encrypted.

### Can Rittal 7979.236 PDU Metered 30 outlets be purchased with a lease?

Yes, the purchase is available both on credit and with an interest-free installment plan. Learn more about installments and credit options: https://aio.lv/en/payment#b3

### Can this product be purchased for a company (with VAT)?

Yes. AiO.lv works with legal entities in Latvia and across Europe. The product price already includes VAT. For certain product categories, as well as for companies from other EU countries with a valid VAT number, a 0% VAT rate may apply. We issue the invoice immediately after the order is placed, support electronic BIS invoices, and automatically generate all necessary accounting documents. You can complete the purchase for a company online — simply select the company profile and choose bank transfer as the payment method during checkout.

### What is the warranty period?

All Rittal products come with an official 2 Years warranty. It covers all manufacturing defects and malfunctions that may occur during use. The warranty is valid at all authorized Rittal service centers and through AiO.lv

### Can the product be returned after purchase?

Yes, you can return the product within 14 days of purchase if you bought it as a consumer (not a legal entity). Returns are possible without giving any reason — the main condition is that the product retains its original appearance and full set of accessories. We will make the process as simple and convenient as possible: just contact our customer support team, and we will help you arrange the return.

### Where should I contact for warranty service?

For warranty-related questions you can contact the AiO.lv (SIA VSPRO) customer support team. More information about warranty service: https://aio.lv/en/warranty

### How can I tell if this product suits my needs?

When making a choice, we recommend paying attention to the key features: nominal input voltage, maximum current, ac outlets quantity, weight, pdu types, product colour, compatibility with your devices or usage conditions, material quality, functionality, and warranty terms. These characteristics will help you determine how well the model meets your needs.

### Where can I download the instructions for Rittal 7979.236 PDU Metered 30 outlets?

You can download the instructions in PDF format from the “Instructions” section on the product description page. The file contains complete information about installation, setup, and usage.

## Image

https://aio.lv/img/cache/product/12400581/68690350_large.webp