# Contactor Schneider Electric LC1K 3P, rated insulation 690 V, Uimp 8 kV, coil 230 V AC

**URL:** https://aio.lv/en/product--schneider-electric-lc1k0610p5--12399069
**Data updated:** 2026-04-28 17:44 (EEST)
**Category:** Control Systems
**Manufacturer:** Schneider Electric
**Manufacturer code:** LC1K0610P5
**EAN:** 3606489602369
**Warranty:** 2 Years
**Availability:** Available for order
**Price:** 25.49 €
**Prices and availability valid until:** 2026-07-29 23:59
**Price without VAT (21%):** 21.07 EUR
**Can be purchased by legal entities:** Yes (invoice)
**Buy:** https://aio.lv/en/product--schneider-electric-lc1k0610p5--12399069

## Delivery options

| Delivery method | Delivery time | Cost |
|---|---|---|
| Office pickup (2b. Kengaraga str., Riga, Latvia, LV-1063) | 16.07.2026 | free |
| Pickup points | 21.07.2026 | 1.89 EUR |
| Courier delivery to door | 21.07.2026 | 4.99 EUR |

## Summary description

Schneider Electric LC1K is a 3-pole power contactor designed for switching and controlling three-phase circuits. It has a rated insulation voltage of 690 V and rated impulse withstand voltage (Uimp) of 8 kV. The device suits motor control, lighting and heating loads; specified coil voltage is 230 V AC. Compact modular design enables panel mounting.

## Long description

Schneider Electric LC1K0610P5 is a compact three-pole power contactor for switching and controlling three-phase circuits. It has a rated operational current of 6 A and a coil rated at 230 V AC, 50 Hz. The device features one normally open auxiliary contact and is specified with a rated insulation voltage of 690 V and an impulse withstand voltage (Uimp) of 8 kV. Its modular design allows panel or DIN-rail compatible mounting for use in industrial and commercial control panels.
Advantages
The LC1K0610P5 provides electromechanical switching with clear separation between control and load circuits, which simplifies maintenance and replacement. Its three-pole main contacts support three-phase switching of small loads while a single normally open auxiliary contact enables basic status signaling or interlock functions. The 230 V AC coil voltage matches common control supplies, and the compact footprint facilitates installation in switchboards and control cabinets.
Suitable for
 Switching and control of small three-phase motors up to the contactor's 6 A rating
 Control of resistive loads such as electric heaters and convection heaters
 Lighting circuits and small distribution circuits in commercial buildings
 Automation panels where a single normally open auxiliary contact is sufficient for status signaling
When it may not be suitable
This contactor is not suitable for loads that exceed its 6 A rated current; higher current motors or heavy-duty inductive loads require a higher-rated contactor with appropriate inrush current capacity. It also provides only one normally open auxiliary contact, so applications needing multiple auxiliary contacts or both NO and NC contacts will require additional auxiliary blocks or a different model. For DC control voltages or nonstandard coil voltages, choose a contactor with the matching coil specification.
Key specifications
 Number of poles: 3 (three-pole main contacts)
 Rated operational current: 6 A
 Coil voltage and frequency: 230 V AC, 50 Hz
 Auxiliary contacts: 1 normally open (1 NO)
 Rated insulation voltage: 690 V
 Impulse withstand voltage (Uimp): 8 kV
 Type of operation: electromechanical switching for AC loads
 Mounting: panel or DIN-rail compatible mounting
How to use
Install the contactor in a control panel or on a DIN rail following local electrical codes and Schneider Electric installation instructions. Connect the three-phase load conductors to the main power terminals and the supply conductors to the corresponding line terminals. Wire the 230 V AC control supply to the coil terminals. Use the normally open auxiliary contact for status indication, interlock circuits, or to drive control relays. Verify terminal tightening torque and appropriate protective device settings, then perform no-load operational tests before commissioning.
What to consider before purchase
 Confirm the continuous and starting load current does not exceed the contactor's 6 A rating
 Ensure the control supply is 230 V AC, 50 Hz to match the coil
 Assess whether a single normally open auxiliary contact meets your control and signaling requirements
 Check compatibility with existing mounting space, wiring layout, and protective devices in the panel
Usage recommendations
Pair the LC1K0610P5 with correctly sized overload protection and protective devices for the specific motor or load, maintain wiring and ambient temperature within manufacturer guidelines, and perform periodic inspections of contacts and terminal tightness as part of routine maintenance.

## Specifications

| Feature | Value |
|---|---|
| Weight | 0.18 kg |
| Storage temperature (T-T) | -50 - 80 |
| Package weight | 178.25 g |
| Height | 58 mm |
| Width | 45 mm |
| Depth | 57 mm |
| Nominal input voltage | 690 |
| Input frequency | 50/60 |
| Package depth | 65 mm |
| Package height | 50 mm |
| Package width | 65 mm |
| Maximum operating altitude | 2000 m |
| International Protection (IP) code | IP20 |
| Number of poles | 3P |
| Overvoltage category | CAT III |
| Rated insulation voltage | 690 V |
| Maximum inrush current | 6 A |
| Warranty period | 1.5 year(s) |
| Mechanical durability (cycles) | 10000000 |
| Electrical durability (cycles) | 1300000 |
| Rated impulse withstand voltage (Uimp) | 8 kV |

## FAQ

### How much does the Schneider Electric LC1K 3P contactor 230 V AC cost, and is it available for purchase?

The price is 25.49 € (valid at the time of publication and already includes all taxes). The item is available for order — 15 pcs. are in stock, and you can place your purchase right now with delivery across Latvia and Europe or choose pickup at the Riga collection point. We offer favorable purchase terms, including the option to split the payment into convenient monthly installments. Availability and price are updated in real time, so we recommend placing your order in advance.

### If I order this product today, when will I receive my order?

If you place your order today, delivery will be as fast and convenient as possible. You will be able to pick up your order on 16.07.2026 at the Riga pickup point or choose delivery across Latvia and Europe. We carefully inspect every purchase and pack it securely for safe transportation.

### What payment options are available?

AiO.lv offers several payment methods: Bank transfer, Bank cards on-line, Apple Pay, Google Pay. All transactions are 100% secure and encrypted.

### Can this product be purchased for a company (with VAT)?

Yes. AiO.lv works with legal entities in Latvia and across Europe. The product price already includes VAT. For certain product categories, as well as for companies from other EU countries with a valid VAT number, a 0% VAT rate may apply. We issue the invoice immediately after the order is placed, support electronic BIS invoices, and automatically generate all necessary accounting documents. You can complete the purchase for a company online — simply select the company profile and choose bank transfer as the payment method during checkout.

### What is the warranty period?

All Schneider Electric products come with an official 2 Years warranty. It covers all manufacturing defects and malfunctions that may occur during use. The warranty is valid at all authorized Schneider Electric service centers and through AiO.lv

### Can the product be returned after purchase?

Yes, you can return the product within 14 days of purchase if you bought it as a consumer (not a legal entity). Returns are possible without giving any reason — the main condition is that the product retains its original appearance and full set of accessories. We will make the process as simple and convenient as possible: just contact our customer support team, and we will help you arrange the return.

### Where should I contact for warranty service?

For warranty-related questions you can contact the AiO.lv (SIA VSPRO) customer support team. More information about warranty service: https://aio.lv/en/warranty

### Where can I download the instructions for Schneider Electric LC1K 3P contactor 230 V AC?

You can download the instructions in PDF format from the “Instructions” section on the product description page. The file contains complete information about installation, setup, and usage.

## Image