{{ totalProductsCount }}

Grozā {{totalProductsCount}} prece(s)

Summa:
{{sum | formatAmount}}

Jūsu grozs ir tukšs

header-product Barošanas sadale APC NetShelter APDU11250SW — 42 AC ligzdas (C13/C15/C19/C21), 3‑fāžu, 0U, 400 V, 60 A, NMC3
2,686.99 €

Barošanas sadale APC NetShelter APDU11250SW — 42 AC ligzdas (C13/C15/C19/C21), 3‑fāžu, 0U, 400 V, 60 A, NMC3

APC NetShelter APDU11250SW PDU 42 ligzdas 3‑fāžu Photo 1
APC NetShelter APDU11250SW PDU 42 ligzdas 3‑fāžu Photo 2
APC NetShelter APDU11250SW PDU 42 ligzdas 3‑fāžu Photo 1
APC NetShelter APDU11250SW PDU 42 ligzdas 3‑fāžu Photo 2
Sekojiet līdzi cenu izmaiņām Vai sekojat līdzi cenu izmaiņām
Skatieties, kā samazinās cena

Atstājiet savu adresi - tiklīdz produkta cena samazināsies, jūs uzreiz par to uzzināsiet.

Vai sekojat līdzi cenu izmaiņām

Barošanas sadale APC NetShelter APDU11250SW — 42 AC ligzdas (C13/C15/C19/C21), 3‑fāžu, 0U, 400 V, 60 A, NMC3

{{email}}
Vai sekojat līdzi cenu izmaiņām

Barošanas sadale APC NetShelter APDU11250SW — 42 AC ligzdas (C13/C15/C19/C21), 3‑fāžu, 0U, 400 V, 60 A, NMC3

{{email}}
{{selectedOffer && selectedOffer.price | formatAmount}}

Īss apraksts

APC NetShelter APDU11250SW ir 0U skapja barošanas sadales bloks ar 42 AC ligzdām — C13, C15, C19 un C21. Metered tipa, 3‑fāžu PDU ar nominālo ieeju 400 V, maksimālo strāvu 60 A un frekvenci 50/60 Hz. Pārvaldāms caur NMC3 platformu; paredzēts datu centru un serveru skapju centralizētai strāvas sadalei un uzraudzībai. Atbilst RoHS.
Pieejams par cenu 2,686.99 €: 6 gab.
Kopumā pieejams pasūtīšanai: 18 gab.
Garantija: 2 gadi
Artikuls: 12246257
free shipment

Vislētākā piegāde:

Unisend LV

Pakomāti

Unisend LV

Cena

1.79 €

Piegādāsim

{{selectedOffer.parcelStationDeliveryString}}

Klientu centrs
Ķengaraga iela 2b, Rīga, Latvija, LV-1063
10.08.2026 {{selectedOffer.officeDeliveryString}}
Bezmaksas
Piegāde ar kurjeru Lielgabarīta pasūtījuma gadījumā piegādes cena var palielināties!
13.08.2026 {{selectedOffer.courierDeliveryString}}
No 9.68 € (Svars: 11.70 kg)
Piegāde līdz saņemšanas punktiem
Unisend LV / Venipak Locker LV / Latvijas Pasts pakomāts / DPD Paku skapis / Omniva LV / Latvijas Pasts nodaļa
13.08.2026 {{selectedOffer.parcelStationDeliveryString}}
No 1.79 €
payment
Maksājumu veidi:
Skaidrā naudā, Pārskaitījums, Bankas karte on-line, Apple Pay, Google Pay, Līzings juridiskām personām
Līzings juridiskai personai: no 93.51 €/mēn.
Pieejams privātiem klientiem par cenu 2,828.99 €: 6 gab.
Kopā lētāk
{{product.price | formatAmount}}
{{product.title}}
{{productBundle.reference.specialPrice | formatAmount}}
{{productBundle.title}}
{{productBundlePreviousPrice | formatAmount}}
{{productBundleSpecialPrice | formatAmount}}

Jūs ietaupāt {{productBundleYouSave | formatAmount}}

Informācija par produktu

Apraksts

APC NetShelter APDU11250SW ir 0U plauktā montējams, mērīts un pārvaldāms barošanas sadales bloks (PDU) trīsfāzu IT barošanai. Ierīce nodrošina 42 maiņstrāvas kontaktligzdas ar kombinētām iespējām (C13, C15, C19 un C21) kompakta 2,2 collu (5,6 cm) platumā, pieņem 400 V nominālo ieeju līdz 60 A un darbojas 50/60 Hz frekvencē. PDU tiek pārvaldīts caur NMC3 platformu un atbalsta integrāciju ar EcoStruxure IT, nodrošinot attālinātu kontaktligzdu pārslēgšanu, PDU līmeņa mērošanu ar aptuveni 1% precizitāti un tīkla savienojumu caur 1 Gbps Ethernet portu. Ierīcei ir divi saišu porti kas ļauj kaskādēt līdz 32 PDU, divi vides sensora porti un 3 m ieejas kabelis ar IEC-309 20 A 3P+N+PE spraudni. Ierīce atbilst vairākām starptautiskām drošības un vides prasībām, tostarp RoHS.

Priekšrocības

APDU11250SW nodrošina lielu kontaktligzdu blīvumu un izvietošanas elastību, pateicoties 4-in-1 kombinētajām kontaktligzdām, kas samazina nepieciešamību pēc adapteriem un atbalsta dažādu IT iekārtu pieslēgšanu. Iebūvētā mērošana un pārslēdzamās kontaktligzdas ļauj centralizēti pārraudzīt un kontrolēt enerģijas patēriņu, identificēt potenciālas pārslogojuma situācijas un veikt attālinātas restartēšanas. NMC3 pārvaldība un EcoStruxure IT integrācija nodrošina konfigurācijas un uzraudzības iespējas, savukārt kaskādēšanas iespējas un tīkla porta koplietošana atvieglo vairākas ierīces vadību.

Piemērots

  • Serveru skapjiem un datu centru skapjiem ar augstām kontaktligzdu prasībām
  • Tīkla skapjiem un telekomunikāciju stendiem, kur nepieciešamas dažādu tipu kontaktligzdas (C13/C15/C19/C21)
  • Videi, kur nepieciešama attālā kontaktligzdu pārvaldība un centralizēta elektroenerģijas uzskaite
  • Izvietojumiem, kas paredz kaskādēšanu vairākām PDU ierīcēm un centralizētu kontroli

Galvenās specifikācijas

  • Formfaktors: 0U plauktā montējams, platums 2,2 collas (5,6 cm)
  • Ieeja: trīsfāzu nomināls 400 V, līdz 60 A, 50/60 Hz
  • Kontaktligzdas: 42 kombinētās kontaktligzdas, saderīgas ar C13, C15, C19 un C21
  • Mērīšana: PDU līmeņa mērošana ar aptuveni 1% precizitāti
  • Tīkls: 1 Gbps Ethernet ports (10/100/1000), piekļuve caur SNMP un CLI
  • Kaskāde: divi saišu porti, iespēja kaskādēt līdz 32 PDU, tīkla porta koplietošanas atbalsts
  • Sensora porti: divi vides sensora porti (sensori tiek pārdoti atsevišķi)
  • Kabelis: 3 m ieejas kabelis ar IEC-309 20 A 3P+N+PE savienotāju
  • Darbības temperatūra: darbināms pilnā slodzē pie paaugstinātām apkārtējās vides temperatūrām (līdz 60 °C)
  • Sertifikācija: atbilstība starptautiskām prasībām un RoHS

Kā lietot

Uzstādiet PDU 0U pozīcijā atbilstošā plauktā un pievienojiet ieejas kabeli trīsfāzu barošanas avotam, kas atbilst ierīces sprieguma un strāvas prasībām. Savienojiet tīkla portu ar pārvaldības tīklu un konfigurējiet ierīci, izmantojot NMC3, tīmekļa saskarni, SNMP vai CLI. Ja nepieciešams, pievienojiet ārējos vides sensorus temperatūras vai mitruma uzraudzībai. Izmantojiet pārvaldības interfeisu, lai uzraudzītu enerģijas patēriņu, pārslēgtu kontaktligzdas attālināti, iestatītu brīdinājumu sliekšņus un plānotu uzturēšanas operācijas.

Lietošanas ieteikumi

Pirms uzstādīšanas pārliecinieties, ka plaukta elektriskā instalācija un barošanas sadale atbalsta trīsfāzu 400 V pie nepieciešamā strāvas līmeņa. Saglabājiet slodžu līdzsvaru starp fāzēm, izmantojiet NMC3 funkcijas mērošanai un pārvaldībai, lai novērstu pārslogojumus, un apsveriet kaskādēšanu ar tīkla porta koplietošanu, ja pārvaldāt vairākas ierīces, lai vienkāršotu tīkla savienojumus un centrētu kontroli.

Parametri

Maksimālā strāva: The greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
60 A
Nominālais ieejas spriegums: The voltage which the manufacturer recommends that the device needs to operate normally.
400
Izeju skaits: The number of sockets in the device where AC electrical power can be connected.
42 Maiņstrāvas izvade (-s)
Statņa kapacitāte: The spase that device fill in rack.
0U
Maiņstrāvas izeju tipi: The type of outlet for AC electricity.
C13 uzmava, C15 uzmava, C19 uzmava, C21 uzmava
PDU veidi: A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP.
Mērāms
Visi parametri

Informācija par iepakojumu

Iepakojuma augstums: The distance from the top to the bottom of the packaging.
2110 mm
Iepakojuma dziļums: The distance from the front to the back of the packaging.
262 mm
Iepakojuma platums: The distance from one side of the packaging to the other.
132 mm
Iepakojuma svars: Weight of the packaged product.
17000 g

Svars&dimensijas

Svars: Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
11.7 kg
Augstums: The measurement of the product from head to foot or from base to top.
1826 mm
Dziļums: The distance from the front to the back of something.
75 mm
Platums: The measurement or extent of something from side to side.
56 mm

Sertifikāti

Atbilstības sertifikāti: Indicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
RoHS

Enerģijas pārvaldība

Fāžu skaits:
3
Ielādes ietilpība:
34600 VA
Niminālais izejas spriegums: The voltage which the manufacturer states that the device can produce.
400
Maksimālā strāva: The greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
60 A
Maiņstrāvas ievades frekvence:
50/60
Nominālais ieejas spriegums: The voltage which the manufacturer recommends that the device needs to operate normally.
400

Vadības īpašības

Vadības platforma:
NMC3

Savienojamība

USB pieslēgvietu skaits:
1
Ethernet LAN (RJ-45) pieslēgvietu skaits: Number of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet.
5
Maiņstrāvas izeju tipi: The type of outlet for AC electricity.
C13 uzmava, C15 uzmava, C19 uzmava, C21 uzmava
Izeju skaits: The number of sockets in the device where AC electrical power can be connected.
42 Maiņstrāvas izvade (-s)

Dizains

Produkta krāsa: The colour e.g. red, blue, green, black, white.
Melns
Statņa kapacitāte: The spase that device fill in rack.
0U
Tips: Characteristics of the device.
Trīsfāžu
PDU veidi: A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP.
Mērāms

Līdzīgi produkti

{{product.title}} Skatīt vairāk Paslēpt detaļas

{{highlightedFeature.featureTitle}}:

{{getProductFeatureValueById(product, highlightedFeature.featureId)}}

{{product.price | formatAmount}}
Varbūt derēs
{{product.manufacturerName}}
{{product.categoryName}}
{{product.title}}
{{product.specialPrice}}
{{product.price}}
Noliktavā
Noliktava Pieejams Piegāde uz veikalu Pārdošanas cena
WH354 6 10.08.2026 Vislabākā piegāde
2,828.99 €
Pieejams tikai juridiskām personām
Noliktava Pieejams Piegāde uz veikalu Pārdošanas cena
EU9 6 10.08.2026 Vislabākā piegāde
2,686.99 € Labākā cena
WH109 6 24.08.2026
3,416.99 €
2,828.99 €
Pieejams: 6
Piegādes datums: 10.08.2026 Vislabākā piegāde
Noliktava: WH354
Pieejams tikai juridiskām personām
2,686.99 €
Pieejams: 6
Piegādes datums: 10.08.2026 Vislabākā piegāde
Noliktava: EU9
3,416.99 €
Pieejams: 6
Piegādes datums: 24.08.2026
Noliktava: WH109

Pircēju atsauksmes

Pircēju jautājumi

Biežāk uzdotie jautājumi

Cik maksā un vai ir pieejams pārdošanai APC NetShelter APDU11250SW PDU 42 ligzdas 3‑fāžu?

Cena ir 2,686.99 € (spēkā publicēšanas brīdī un jau ietver visus nodokļus). Prece ir pieejama pasūtīšanai — noliktavā ir 18 gab., un jūs varat veikt pirkumu jau tagad ar piegādi pa visu Latviju un Eiropu vai izvēlēties saņemt pasūtījumu Rīgas izsniegšanas punktā. Mēs piedāvājam izdevīgus pirkuma nosacījumus, tostarp iespēju sadalīt maksājumu ērtos ikmēneša maksājumos. Pieejamība un cena tiek atjauninātas reāllaikā, tāpēc iesakām veikt pasūtījumu savlaicīgi.

Ja es pasūtīšu šo produktu šodien, kad saņemšu pasūtījumu?

Veicot pasūtījumu šodien, piegāde būs maksimāli ātra un ērta. Pasūtījumu varēsiet saņemt 10.08.2026 Rīgas izsniegšanas punktā vai izvēlēties piegādi pa visu Latviju un Eiropu. Mēs rūpīgi pārbaudām katru pirkumu un iepakojam to drošai transportēšanai.

Kādi ir apmaksas veidi?

AiO.lv piedāvā vairākus apmaksas veidus: Skaidrā naudā, Pārskaitījums, Bankas karte on-line, Apple Pay, Google Pay, Līzings juridiskām personām. Visas transakcijas ir drošas un šifrētas.

Vai šo produktu var iegādāties uzņēmumam (ar PVN)?

Jā. AiO.lv strādā ar juridiskām personām visā Latvijā un Eiropā. Preces cena jau ietver PVN. Atsevišķām preču kategorijām, kā arī uzņēmumiem no citām ES valstīm ar derīgu PVN numuru, var tikt piemērota 0% PVN likme. Rēķinu izrakstām uzreiz pēc pasūtījuma noformēšanas, atbalstām e-rēķinus BIS sistēmā un automātiski sagatavojam pavaddokumentus. Pirkumu uz uzņēmumu var noformēt tiešsaistē — pasūtījuma veikšanas laikā izvēlieties uzņēmuma profilu un bezskaidras naudas apmaksas veidu.

Kāds ir garantijas termiņš?

Uz APC produkciju tiek nodrošināta oficiālā garantija uz 2 gadi. Tā sedz visus ražošanas defektus un bojājumus, kas var rasties ierīces lietošanas laikā. Garantija ir spēkā visos autorizētajos APC servisa centros un caur AiO.lv

Vai preci var atgriezt pēc iegādes?

Jā, jūs varat atgriezt preci 14 dienu laikā no iegādes brīža, ja iegāde veikta kā patērētājam (nevis juridiskai personai). Atgriešana iespējama bez iemesla paskaidrošanas — galvenais, lai prece saglabā savu preces izskatu un pilnu komplektāciju. Mēs padarīsim procesu pēc iespējas vienkāršāku un ērtāku: pietiek sazināties ar mūsu klientu atbalsta dienestu, un mēs palīdzēsim noformēt atgriešanu.

Kur vērsties garantijas gadījumā?

Par garantijas jautājumiem jūs varat vērsties AiO.lv (SIA VSPRO) klientu atbalsta dienestā. Mēs palīdzēsim ar konsultāciju, garantijas gadījuma noformēšanu un sadarbību ar sertificētiem servisa centriem.

Kā saprast, vai šis produkts ir piemērots manām vajadzībām?

Vispirms nosakiet, kādiem uzdevumiem plānojat izmantot ierīci. Izvēloties ir svarīgi ņemt vērā galvenās īpašības, piemēram, maksimālā strāva, nominālais ieejas spriegums, izeju skaits, statņa kapacitāte, maiņstrāvas izeju tipi, pdu veidi, kā arī citus parametrus. Šo rādītāju salīdzināšana ar jūsu prasībām palīdzēs saprast, cik labi ierīce atbilst jūsu vajadzībām. Ja nepieciešams, mēs esam gatavi sniegt bezmaksas konsultāciju un palīdzēt izvēlēties piemērotāko risinājumu.

Kur var lejupielādēt instrukciju APC NetShelter APDU11250SW PDU 42 ligzdas 3‑fāžu?

Instrukciju PDF formātā var lejupielādēt preces apraksta lapas sadaļā “Instrukcijas”. Fails satur pilnīgu informāciju par uzstādīšanu, iestatīšanu un lietošanu.
warranty
14 dienas preces atgriešanai Mēs esam pārliecināti par kvalitāti, bet, ja pirkums neder — jums ir 14 dienas, lai mierīgi atgrieztu preci.
shipping
Ātra piegāde Saņemiet pasūtījumus maksimāli ātri — līdz pašām durvīm, uz pakomātiem vai saņemšanas punktiem visā Latvijā un ES.
payment
Droši maksājumi Maksājiet tā, kā jums ērtāk: skaidrā naudā, ar VISA, MasterCard, Apple Pay, Google Pay, bankas pārskaitījumu vai 0% līzingu.
warranty
Kvalitāte kopš 2008. gada AiO.lv darbojas tirgū jau vairāk nekā 18 gadus un ir ieguvis uzticību — vairāk nekā 6000 patiesu pozitīvu atsauksmju Google.