Product specification Mixing valve kit Afriso ProClick ARV 485 ProClick DN32 Rp1 1/4 Kvs 18 with electric actuator ARM 343 ProClickA

Description
The Mixing valve kit Afriso ProClick ARV 485 ProClick DN32 Rp1 1/4 Kvs 18 with electric actuator ARM 343 ProClickA is a factory-matched assembly for hydraulic temperature control. The kit combines a 4-way rotary mixing valve with a ProClick electric actuator to blend supply and return flows and regulate medium temperature in heating and cooling circuits. It is intended for installation in distribution manifolds, boiler circuits and fan coil lines where precise proportional or on/off control of flow and temperature is required.
Advantages
The compact modular design provides straightforward installation and service access without need for special tools. The rotary mixing valve ensures smooth proportional control and stable temperature blending across the rated flow range, while the electric actuator offers reliable position control and simple electrical integration. Materials and construction are selected for compatibility with common heating and chilled water systems, reducing risk of leakage and ensuring long-term operation under typical system pressures and temperatures.
Suitable for
- Hydronic heating distribution manifolds
- Boiler return or supply temperature control
- Fan coil unit temperature regulation
- Small to medium commercial heating and cooling circuits
Key specifications
- Valve type: 4-way rotary mixing valve
- Nominal diameter: DN32
- Threaded connection: Rp 1 1/4
- Kvs (flow coefficient): 18
- Actuator type: Electric proportional/on-off actuator with ProClick mounting
- Intended media: Heating and chilled water systems
- Control modes: Proportional and on/off control capability
How to use
Install the mixing valve into the hydraulic circuit according to flow direction marking and apply the actuator with the ProClick mounting until it locks. Connect electrical wiring to the actuator following the manufacturer’s control signal requirements and local electrical codes. Commission the assembly by verifying correct valve travel, control response and leak-tightness at operating pressure. Adjust control setpoints in the system controller so the mixer modulates to maintain the required medium temperature.
Usage recommendations
For reliable performance, flush the system prior to installation to remove debris, ensure compatibility of system fluid and additives, and follow recommended torque values for threaded connections. Use appropriate isolation valves and strainers upstream to reduce maintenance, and perform periodic functional checks of actuator travel and valve sealing.