Product specification RM fiber optic patchcord duplex 9/125 µm E2000 APC to LC 3.0 m

Description
RM fiber optic patchcord duplex 9/125 µm E2000 APC to LC 3.0 m is a single-mode duplex cable designed for reliable optical connections in telecom, data center and laboratory environments. The cable uses 9/125 µm single-mode fiber and terminates with an E2000 APC connector on one end and an LC connector on the other, providing stable, low-reflection links suitable for patching, inter-equipment cabling and precise measurement tasks. The 3.0 m length offers convenient reach for short runs between racks, panels and active equipment.
Advantages
The duplex construction provides two independent optical channels in a single jacket for simultaneous transmit and receive paths. The E2000 APC termination ensures low back-reflection thanks to its angled-polish ferrule, while the LC termination delivers a compact footprint for high-density panels and transceivers. The cable is engineered to offer consistent insertion loss and mechanical durability for repeated mating cycles and routine handling.
Suitable for
- Patching between distribution panels and transceivers in data centers
- Interconnecting telecom equipment and optical line terminals
- Laboratory testing and fiber characterization where single-mode performance is required
- Connections in high-density optical cabinets and patch panels
Key specifications
- Fiber type: single-mode 9/125 µm
- Configuration: duplex (two fibers in one jacket)
- Connector A: E2000 APC (angled polish)
- Connector B: LC (standard simplex/duplex housing)
- Cable length: 3.0 m
- Polish type: APC on E2000 end; PC/UPC not applicable on that end
- Typical use: single-mode optical links for telecom and data center applications
How to use
Route the patchcord avoiding sharp bends and mechanical strain; maintain the minimum bend radius recommended for single-mode 9/125 µm fiber. Clean connector endfaces before mating using appropriate fiber cleaning tools to ensure low insertion loss and prevent damage. Insert the E2000 APC and LC connectors into their respective adapters or transceiver ports until they click or seat fully, observing port alignment and keying. When disconnecting, pull on the connector body rather than the cable jacket to avoid stressing the fiber.
Usage recommendations
Store the cable coiled without tight loops and keep dust caps on unused connectors. For measurement or high-precision links, perform an inspection and insertion loss test after installation. Replace the patchcord if endface damage or excessive loss is detected.