Product specification Uponor Base Flexiboard with Pump Logic X-25, 6x, 230V heating system control module

Description
Uponor Base Flexiboard with Pump Logic X-25, 6x, 230V heating system control module is a centralized control unit designed for multi-circuit underfloor and hydronic heating installations. Supplied in a six-circuit configuration and operating from a 230V supply, the unit integrates Pump Logic X-25 pump control to manage circulation pumps and coordinate flow between circuits. The module is intended for residential and light-commercial systems where a compact, organized control board simplifies wiring and pump integration.
Advantages
The control module combines multi-circuit manifold connections with an integrated pump controller to reduce installation time and minimize external wiring. Pump Logic X-25 provides coordinated pump management to improve circulation efficiency and reduce noise from frequent pump cycling. The 230V compatibility ensures straightforward connection to standard mains supplies, while the six-circuit configuration supports medium-sized zoning needs without requiring additional expansion panels.
Suitable for
- Underfloor heating systems with up to six independent circuits
- Hydronic heating installations in residential buildings
- Light-commercial projects requiring centralized pump and circuit management
- Retrofit installations where compact control boards simplify replacement of distributed components
Key specifications
- Number of circuits: six-circuit configuration
- Supply voltage: 230 V mains operation
- Integrated pump control: Pump Logic X-25 for coordinated pump management
- Application: underfloor heating and general hydronic heating systems
- Mounting: wall- or cabinet-mountable control board format for organized installation
How to use
Mount the Flexiboard in a dry, accessible location near the manifold and central heating components. Connect the six circuit outputs to the respective manifold actuators or thermostatic heads, and wire the Pump Logic X-25 to the circulation pump following local electrical regulations. Provide a 230V mains supply to the unit and configure any required pump control settings according to the hydronic system design. Commission each circuit sequentially to verify valve operation, flow balancing and pump interaction before placing the system into normal operation.
Usage recommendations
For reliable operation, ensure the control module is installed by a qualified heating or electrical professional, components are protected from moisture, and the circulation pump is sized to match the combined flow requirements of the six circuits. Periodic checks of wiring connections and actuator responses will help maintain consistent heating performance.