Insulated Phase Cable-to-Pole Connector ALPAR ZKS-F (model ANN.02.47)
Insulated Phase Cable-to-Pole Connector ALPAR ZKS-F (model ANN.02.47)
In cart {{totalProductsCount}} item(s)
Your cart is empty
Insulated Phase Cable-to-Pole Connector ALPAR ZKS-F (model ANN.02.47)
Leave your address - as soon as the price of the product goes down, you'll know about it right away
Insulated Phase Cable-to-Pole Connector ALPAR ZKS-F (model ANN.02.47)
Insulated Phase Cable-to-Pole Connector ALPAR ZKS-F (model ANN.02.47)
ALPAR ZKS-F (model ANN.02.47) is an insulated phase cable-to-pole connector designed to provide a secure mechanical and electrical connection between an overhead phase conductor and a pole or support structure. Intended for use in low- and medium-voltage distribution networks, this connector offers an insulated termination point for a single phase conductor, enabling safe line terminations, repairs and retrofit connections on distribution poles. The connector is manufactured to maintain electrical continuity while preserving insulation at the attachment point.
The insulated ALPAR ZKS-F connector combines mechanical strength with electrical insulation at the connection point, reducing the need for additional insulating components. Its design facilitates straightforward installation and reliable retention of the conductor under typical overhead line loads. The connector supports durable electrical contact and limits exposure of conductive parts, contributing to operational safety and reduced maintenance requirements.
Select an appropriate attachment point on the pole or support structure and ensure the conductor is de-energized before starting work. Position the ALPAR ZKS-F connector onto the conductor according to the conductor diameter and manufacturer guidelines, then secure the mechanical clamp to retain the conductor. Fasten the connector to the pole mounting point using suitable bolts or pins for the pole material. Verify tightness of mechanical connections and ensure the insulating housing fully covers exposed conductive elements before re-energizing the line.
Use this connector only on de-energized conductors during installation and follow applicable safety standards and local regulations. Inspect connections periodically for corrosion, mechanical wear or damage to insulation, and replace the connector if its integrity is compromised. Choose mounting hardware appropriate for the pole material and environment to maintain long-term mechanical stability.