Leave your address - as soon as the price of the product goes down, you'll know about it right away
Terminal connector end clamp ALPAR Z201 for cable attachment 2×16–35 mm²
Terminal connector end clamp ALPAR Z201 for cable attachment 2×16–35 mm²
In cart {{totalProductsCount}} item(s)
Your cart is empty
Terminal connector end clamp ALPAR Z201 for cable attachment 2×16–35 mm²
Leave your address - as soon as the price of the product goes down, you'll know about it right away
Terminal connector end clamp ALPAR Z201 for cable attachment 2×16–35 mm²
Terminal connector end clamp ALPAR Z201 for cable attachment 2×16–35 mm²
ALPAR Z201 is an end terminal connector clamp designed to secure and electrically connect two conductors with cross-sections from 16 to 35 mm². The clamp provides mechanical fixation and strain relief for cable terminations in electrical installations, switchgear, distribution panels and industrial equipment. Constructed for reliable contact and stable mounting, this terminal connector is suitable for applications where a compact, robust conductor clamp is required.
The clamp ensures consistent mechanical pressure across the conductor contact area to reduce contact resistance and improve connection stability. Its design supports two conductors simultaneously, enabling neat cable routing and saving space in connection compartments. Manufactured to withstand routine electrical and mechanical stresses, the connector delivers reliable conductor clamping and strain relief without complex installation procedures.
Prepare conductors by stripping insulation to the required length following installation standards. Insert each conductor into the clamp openings and tighten the fastening screws or bolts until the conductors are securely fixed and no movement is present. Ensure the clamp is mounted on the intended terminal point or busbar and that mechanical strain relief is achieved by routing and securing cables appropriately. Verify electrical continuity and torque values according to project or manufacturer guidelines before energizing the circuit.
Use this clamp with conductors of the specified cross-section range (16–35 mm²) and confirm correct stripping length and torque settings. Regularly inspect installed connections for signs of loosening, corrosion or overheating and retighten or replace components as needed. Follow applicable local electrical codes and safety practices during installation and maintenance.
{{highlightedFeature.featureTitle}}:
{{getProductFeatureValueById(product, highlightedFeature.featureId)}}