Terminal connector end clamp ALPAR Z202 for cable range 4×16–35 mm²
Terminal connector end clamp ALPAR Z202 for cable range 4×16–35 mm²
In cart {{totalProductsCount}} item(s)
Your cart is empty
Terminal connector end clamp ALPAR Z202 for cable range 4×16–35 mm²
Leave your address - as soon as the price of the product goes down, you'll know about it right away
Terminal connector end clamp ALPAR Z202 for cable range 4×16–35 mm²
Terminal connector end clamp ALPAR Z202 for cable range 4×16–35 mm²
ALPAR Z202 is an end terminal clamp designed for secure termination of multi‑core or parallel conductors with a cable cross‑section range of 4×16–35 mm². The connector provides a stable mechanical grip and reliable electrical contact for power distribution, grounding and cable junction applications. Intended for use in switchgear and distribution panels, this terminal clamp supports consistent conductor alignment and reduces the risk of loosening under vibration or thermal cycling.
The ALPAR Z202 end clamp combines a compact form factor with robust contact pressure to ensure low electrical resistance and long‑term stability. Constructed for easy installation, it enables consistent termination quality across multiple conductors and maintains contact integrity in demanding environments. The design minimizes conductor deformation while providing sufficient mechanical retention for parallel and multi‑core cables.
Prepare conductor ends by stripping insulation to the recommended length for the clamp and ensure conductors are clean and free of oxidation or contaminants. Insert the conductors into the terminal clamp so that they are aligned and fully seated. Tighten the clamp to the torque values recommended for similar class terminal clamps to achieve secure mechanical and electrical contact; use a calibrated torque driver if precise torque control is required. After installation, check for firm retention and verify continuity and contact resistance with appropriate test equipment.
Use the ALPAR Z202 within the specified cable cross‑section range and follow standard electrical installation practices. Select correct conductor preparation and tightening torque to avoid conductor damage or insufficient contact. Regular visual inspection and periodic testing of connections are advised in installations subject to vibration, temperature variation or heavy current loads.