Terminal cable lug ALPAR Z404 for 4×70–120 mm² conductors, end connector
Terminal cable lug ALPAR Z404 for 4×70–120 mm² conductors, end connector
In cart {{totalProductsCount}} item(s)
Your cart is empty
Terminal cable lug ALPAR Z404 for 4×70–120 mm² conductors, end connector
Leave your address - as soon as the price of the product goes down, you'll know about it right away
Terminal cable lug ALPAR Z404 for 4×70–120 mm² conductors, end connector
Terminal cable lug ALPAR Z404 for 4×70–120 mm² conductors, end connector
ALPAR Z404 is an end terminal cable lug designed to terminate four separate conductors with cross-sections from 70 to 120 mm². It ensures a stable mechanical and electrical connection in low-voltage power installations and is intended for use where multiple large conductors must be joined or connected to busbars, busbars tails, distribution panels, switchgear or junction boxes. The construction supports reliable current transfer and reduces the risk of loose connections in high-current applications.
The terminal lug offers a compact design that accommodates four conductors in a single solid end connector, enabling space-efficient terminations. Its dimensions and conductor range allow use with commonly applied 70–120 mm² cables without additional adapters. The product provides secure clamping and consistent electrical contact area to minimise heating and voltage drop under load. Materials and manufacturing ensure mechanical strength suitable for typical low-voltage power distribution tasks.
Strip each conductor to the recommended insulation removal length, insert all conductors fully into the respective entry of the cable lug, and ensure conductor strands are neatly gathered. Apply the manufacturer-recommended crimping or compression method using an appropriate die or tool for the specified conductor size range to achieve a gas-tight connection. After crimping, inspect the joint for proper compression and secure the lug to the terminal stud or busbar using the correct bolt and torque for the system. Follow local electrical regulations and safety procedures during installation.
Verify conductor material compatibility and use the correct crimping tool and die set rated for 70–120 mm² conductors. Confirm bolt size and torque values for the mating terminal to ensure reliable mechanical and electrical performance. Perform periodic inspections in high-load or vibration-prone installations.