header-product PDU APC NetShelter Rack Advanced 3Phase 11kW 400V 16A 42 Outlets
1,755.99 €

PDU APC NetShelter Rack Advanced 3Phase 11kW 400V 16A 42 Outlets

PDU APC NetShelter Rack Advanced Photo 1
PDU APC NetShelter Rack Advanced Photo 2
PDU APC NetShelter Rack Advanced Photo 3
PDU APC NetShelter Rack Advanced Photo 4
PDU APC NetShelter Rack Advanced Photo 5
PDU APC NetShelter Rack Advanced Photo 6
PDU APC NetShelter Rack Advanced Photo 7
PDU APC NetShelter Rack Advanced Photo 8
PDU APC NetShelter Rack Advanced Photo 9
PDU APC NetShelter Rack Advanced Photo 10
PDU APC NetShelter Rack Advanced Photo 11
PDU APC NetShelter Rack Advanced Photo 12
PDU APC NetShelter Rack Advanced Photo 1
PDU APC NetShelter Rack Advanced Photo 2
PDU APC NetShelter Rack Advanced Photo 3
PDU APC NetShelter Rack Advanced Photo 4
PDU APC NetShelter Rack Advanced Photo 5
PDU APC NetShelter Rack Advanced Photo 6
PDU APC NetShelter Rack Advanced Photo 7
PDU APC NetShelter Rack Advanced Photo 8
PDU APC NetShelter Rack Advanced Photo 9
PDU APC NetShelter Rack Advanced Photo 10
PDU APC NetShelter Rack Advanced Photo 11
PDU APC NetShelter Rack Advanced Photo 12
Keep track of price changes You keep track of price changes
Watch the price drop

Leave your address - as soon as the price of the product goes down, you'll know about it right away

You keep track of price changes

PDU APC NetShelter Rack Advanced 3Phase 11kW 400V 16A 42 Outlets

{{email}}
You keep track of price changes

PDU APC NetShelter Rack Advanced 3Phase 11kW 400V 16A 42 Outlets

{{email}}
{{selectedOffer && selectedOffer.price | formatAmount}}

Short description

The APC NetShelter Rack PDU Advanced is a metered three-phase power distribution unit with 42 AC outlets, supporting 11kW at 400V or 11.5kW at 415V. It features advanced monitoring for current, humidity, power, temperature, and voltage, ensuring efficient power management in data centers.
Available for order: 5 pcs.
Warranty: 2 Years
SKU: 6962730
free shipment

Cheapest delivery:

Unisend LV

Pick-up points

Unisend LV

Cost

1.79 €

Deliver

{{selectedOffer.parcelStationDeliveryString}}

Customer service center
2b. Kengaraga str., Riga, Latvia, LV-1063
25.08.2026 {{selectedOffer.officeDeliveryString}}
free
Courier Delivery Please note that in case of a large parcel additional delivery costs may apply!
28.08.2026 {{selectedOffer.courierDeliveryString}}
From 7.48 € (Weight: 8.56 kg)
Parcel couriers
Unisend LV / Venipak Pickup LV / Venipak Locker LV / Latvijas Pasts pakomāts / DPD Paku skapis / Omniva LV / Latvijas Pasts nodaļa
28.08.2026 {{selectedOffer.parcelStationDeliveryString}}
From 1.79 €
payment
Payment Methods:
Bank transfer, Leasing for legal entities
Leasing for legal entities: from 61.11 euros per month
Together cheaper
{{product.price | formatAmount}}
{{product.title}}
{{productBundle.reference.specialPrice | formatAmount}}
{{productBundle.title}}
{{productBundlePreviousPrice | formatAmount}}
{{productBundleSpecialPrice | formatAmount}}

You saving {{productBundleYouSave | formatAmount}}

Product information

Description

The APC NetShelter Rack PDU Advanced is a metered three-phase power distribution unit designed for server and networking racks. It supports up to 11 kW at 400 V (11.5 kW at 415 V) and provides 42 AC outlets in a compact 2.2U form factor with color-coded and labeled outlets for simplified deployment and load identification.

Advantages

This PDU offers per-unit power metering accessible via local display and remote network access, 1% metering accuracy for reliable billing and capacity planning, and an alternating-phase outlet layout that improves cord management and load balancing. It includes a hot-swappable Network Management Card (NMC) to maintain network connectivity during NMC replacement, dual Ethernet ports (Gigabit + 10/100) for standardised connectivity and cascading, and two environmental sensor ports for optional temperature and humidity monitoring. The unit is rated to operate at full load up to 60 °C and is UL and CE certified for global deployment.

Suitable for

  • Data center rack power distribution for servers and network equipment
  • Environments requiring accurate per-PDU metering and billing
  • High-density rack deployments where outlet density and compact form factor are important

Key specifications

  • Product: APC NetShelter Rack PDU Advanced (APDU10250ME)
  • Input voltage (nominal): 400 V (supports 415 V)
  • Maximum power: 11 kW at 400 V (11.5 kW at 415 V)
  • Maximum current: 16 A
  • Outlets: 42 AC outlets (4-in-1 combination C13/C19/C15/C21)
  • PDU type: Metered
  • Network: Gigabit Ethernet + secondary 10/100 Ethernet port
  • Environmental monitoring: 2 sensor ports (sensors sold separately)
  • Operating temperature: rated to 60 °C at full load
  • Weight: 5.7 kg
  • Certifications: UL and CE

How to use

Mount the PDU in a compatible 2.2U rack space and connect the input to an appropriate three-phase 400/415 V supply with up to 16 A per phase as specified. Use the local display or the Network Management Card to configure metering, alerts, and network settings. Connect equipment to the color-coded combination outlets, observing breaker and phase labels to distribute load evenly. If needed, cascade PDUs using the secondary Ethernet port and enable Power Sharing through the network settings to maintain NMC functionality during AC loss. Install optional temperature and humidity sensors into the sensor ports for environmental monitoring.

Usage recommendations

For balanced loads and improved cord management, connect devices across the alternating-phase outlet groups and monitor per-PDU metering to avoid overloads; replace the Network Management Card only while the unit is powered to preserve device uptime.

Specifications

Maximum current: The greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
16 A
Nominal input voltage: The voltage which the manufacturer recommends that the device needs to operate normally.
400
AC outlets quantity: The number of sockets in the device where AC electrical power can be connected.
42 AC outlet(s)
Rack capacity: The spase that device fill in rack.
0U
AC outlet types: The type of outlet for AC electricity.
C21 coupler, C19 coupler, C15 coupler, C13 coupler
PDU types: A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP.
Metered
All features

Logistics data

Total carbon footprint (kg of CO2e): The total mean carbon footprint value generated across various lifecycle stages (manufacturing, transportation / logistics, use and end of life) per unit (for one single product) i.e., measured in kilograms CO2e.
8717.32

Packaging data

Package height: The distance from the top to the bottom of the packaging.
1720 mm
Package depth: The distance from the front to the back of the packaging.
116 mm
Package width: The distance from one side of the packaging to the other.
208 mm
Package weight: Weight of the packaged product.
7700 g

Weight & dimensions

Weight: Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
5.7 kg
Height: The measurement of the product from head to foot or from base to top.
1490 mm
Depth: The distance from the front to the back of something.
55 mm
Width: The measurement or extent of something from side to side.
56 mm

Operational conditions

Operating temperature (T-T):
23 - 140
Non-operating altitude:
0 - 15240
Operating altitude:
0 - 3048
Operating relative humidity (H-H):
5 - 95
Storage relative humidity (H-H):
5 - 95
Storage temperature (T-T): The minimum and maximum temperatures at which the product can be safely stored.
-25 - 65
Operating temperature (T-T): The minimum and maximum temperatures at which the product can be safely operated.
-5 - 60

Certificates

Compliance certificates: Indicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
RoHS

Power

Maximum power: The maximum power that can be put into or produced by the device.
11040 W
Power protection features: Features that protect the device against power problems e.g. overload.
Overload
Surge protection:
Yes
Maximum total current draw per phase:
16 A
Number of phases:
3
Load capacity:
11500 VA
Output voltage:
230
Nominal output voltage: The voltage which the manufacturer states that the device can produce.
230
Maximum current: The greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
16 A
AC input frequency:
50 - 60
Nominal input voltage: The voltage which the manufacturer recommends that the device needs to operate normally.
400

Management features

Firmware upgradeable:
Yes
Firmware upgradeable via:
Network, USB
Outlet control:
Turn on, Recycle, Lock-out
Monitoring:
Voltage, Temperature, Power, Humidity, Current

Features

Compatible products: Other products that can be used with this product.
Compatible with most NetShelter SX enclosures and third-party racks
Password protection: The computer, smartphone etc. can only be used when the correct password is entered, therefore making it more secure.
Yes
Security algorithms: Security algorithms are used to provide authentication, cipher key generation, integrity and radio link privacy to users on mobile networks. The security algorithms supported are the ones that can be used with this product.
SNMPv3, SNMP, MD5, DES, 256-bit AES, 192-bit AES, 128-bit AES, SNMPv2
Cable length: How long the cable is.
1.8 m
Colour-coded outlets:
Yes
LED indicators:
Network, Activity, Power
Reset button:
Yes
Daisy chain:
Yes

Ports & interfaces

USB ports quantity:
1
Ethernet LAN (RJ-45) ports: Number of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet.
2
AC outlet types: The type of outlet for AC electricity.
C21 coupler, C19 coupler, C15 coupler, C13 coupler
Power plug: A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
IEC 60309
AC outlets quantity: The number of sockets in the device where AC electrical power can be connected.
42 AC outlet(s)

Design

Regulatory Approvals:
CE, CSA C22.2 No 62368-1, EN 62368-1, FCC part 15 subpart B, UKCA, UL 62368-1
On/off switch: The button which is pressed to switch the device on or off.
Yes
Display: The description of display that can includes display type, resolution, size etc.
LCD
Product colour: The colour e.g. red, blue, green, black, white.
Black
Mounting: What size the mounting head of the product is, to couple it with a camera.
Vertical
Rack capacity: The spase that device fill in rack.
0U
Form factor: The shape or design of the product.
Rackmount
Type: Characteristics of the device.
Three-phase
PDU types: A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP.
Metered

Description

Machine translation. Load original

Similar products

{{product.title}} Show details Hide details

{{highlightedFeature.featureTitle}}:

{{getProductFeatureValueById(product, highlightedFeature.featureId)}}

{{product.price | formatAmount}}
Might be useful
{{product.manufacturerName}}
{{product.categoryName}}
{{product.title}}
{{product.specialPrice}}
{{product.price}}

Customer reviews

Customer questions

FAQ

How much does the PDU APC NetShelter Rack Advanced cost, and is it available for purchase?

The price is 1,755.99 € (valid at the time of publication and already includes all taxes). The item is available for order — 5 pcs. are in stock, and you can place your purchase right now with delivery across Latvia and Europe or choose pickup at the Riga collection point. We offer favorable purchase terms, including the option to split the payment into convenient monthly installments. Availability and price are updated in real time, so we recommend placing your order in advance.

If I order this product today, when will I receive my order?

If you place your order today, delivery will be as fast and convenient as possible. You will be able to pick up your order on 25.08.2026 at the Riga pickup point or choose delivery across Latvia and Europe. We carefully inspect every purchase and pack it securely for safe transportation.

What payment options are available?

AiO.lv offers several payment methods: Bank transfer, Leasing for legal entities. All transactions are 100% secure and encrypted.

Can this product be purchased for a company (with VAT)?

Yes. AiO.lv works with legal entities in Latvia and across Europe. The product price already includes VAT. For certain product categories, as well as for companies from other EU countries with a valid VAT number, a 0% VAT rate may apply. We issue the invoice immediately after the order is placed, support electronic BIS invoices, and automatically generate all necessary accounting documents. You can complete the purchase for a company online — simply select the company profile and choose bank transfer as the payment method during checkout.

What is the warranty period?

All APC products come with an official 2 Years warranty. It covers all manufacturing defects and malfunctions that may occur during use. The warranty is valid at all authorized APC service centers and through AiO.lv

Can the product be returned after purchase?

Yes, you can return the product within 14 days of purchase if you bought it as a consumer (not a legal entity). Returns are possible without giving any reason — the main condition is that the product retains its original appearance and full set of accessories. We will make the process as simple and convenient as possible: just contact our customer support team, and we will help you arrange the return.

Where should I contact for warranty service?

For warranty-related questions you can contact the AiO.lv (SIA VSPRO) customer support team. We will assist with consultation, warranty claim processing, and coordination with certified service centers.

How can I tell if this product suits my needs?

When making a choice, we recommend paying attention to the key features: maximum current, nominal input voltage, ac outlets quantity, rack capacity, ac outlet types, pdu types, compatibility with your devices or usage conditions, material quality, functionality, and warranty terms. These characteristics will help you determine how well the model meets your needs.

Where can I download the instructions for PDU APC NetShelter Rack Advanced?

You can download the instructions in PDF format from the “Instructions” section on the product description page. The file contains complete information about installation, setup, and usage.
warranty
14-Day Return Policy We are confident in our quality, but if the purchase doesn’t fit — you have 14 days to return the product with peace of mind.
shipping
Fast Delivery Get your orders as quickly as possible — right to your door, parcel lockers, or pickup points across Latvia and the EU.
payment
Secure Payment Pay the way you prefer: cash, VISA, MasterCard, Apple Pay, Google Pay, bank transfer, or 0% installment plan.
warranty
Quality Since 2008 AiO.lv has been on the market for over 18 years and has earned trust — with more than 6000 genuine positive reviews on Google.