header-product Power distribution unit APC NetShelter 9000 PDU 24 AC outlets (C13/C15/C19/C21), NEMA L6-20P, 200–208V, 20A, vertical 0U, black
1,355.99 €

Power distribution unit APC NetShelter 9000 PDU 24 AC outlets (C13/C15/C19/C21), NEMA L6-20P, 200–208V, 20A, vertical 0U, black

APC NetShelter 9000 PDU 24 AC outlets Photo 1
APC NetShelter 9000 PDU 24 AC outlets Photo 2
APC NetShelter 9000 PDU 24 AC outlets Photo 3
APC NetShelter 9000 PDU 24 AC outlets Photo 4
APC NetShelter 9000 PDU 24 AC outlets Photo 5
APC NetShelter 9000 PDU 24 AC outlets Photo 6
APC NetShelter 9000 PDU 24 AC outlets Photo 7
APC NetShelter 9000 PDU 24 AC outlets Photo 8
APC NetShelter 9000 PDU 24 AC outlets Photo 1
APC NetShelter 9000 PDU 24 AC outlets Photo 2
APC NetShelter 9000 PDU 24 AC outlets Photo 3
APC NetShelter 9000 PDU 24 AC outlets Photo 4
APC NetShelter 9000 PDU 24 AC outlets Photo 5
APC NetShelter 9000 PDU 24 AC outlets Photo 6
APC NetShelter 9000 PDU 24 AC outlets Photo 7
APC NetShelter 9000 PDU 24 AC outlets Photo 8
Keep track of price changes You keep track of price changes
Watch the price drop

Leave your address - as soon as the price of the product goes down, you'll know about it right away

You keep track of price changes

Power distribution unit APC NetShelter 9000 PDU 24 AC outlets (C13/C15/C19/C21), NEMA L6-20P, 200–208V, 20A, vertical 0U, black

{{email}}
You keep track of price changes

Power distribution unit APC NetShelter 9000 PDU 24 AC outlets (C13/C15/C19/C21), NEMA L6-20P, 200–208V, 20A, vertical 0U, black

{{email}}
{{selectedOffer && selectedOffer.price | formatAmount}}

Short description

APC NetShelter 9000 PDU is a vertical, 0U rack power distribution unit with 24 AC outlets (mix of C13, C15, C19 and C21 couplers) and a NEMA L6-20P input plug. Designed for 200–208 V nominal input/output and up to 20 A maximum current, it fits NetShelter racks to supply multiple devices and manage power in data centers, server rooms and network cabinets. Certified to CUL, FCC 15 A, IEC 62368-1 and PSE standards.
Available at price 1,355.99 €: 2 pcs.
Total available for order: 6 pcs.
Warranty: 2 Years
SKU: 10808230
free shipment

Cheapest delivery:

Unisend LV

Pick-up points

Unisend LV

Cost

1.79 €

Deliver

{{selectedOffer.parcelStationDeliveryString}}

Customer service center
2b. Kengaraga str., Riga, Latvia, LV-1063
11.08.2026 {{selectedOffer.officeDeliveryString}}
free
Courier Delivery Please note that in case of a large parcel additional delivery costs may apply!
14.08.2026 {{selectedOffer.courierDeliveryString}}
From 5.42 € (Weight: 5.61 kg)
Parcel couriers
Unisend LV / Venipak Pickup LV / Venipak Locker LV / Latvijas Pasts pakomāts / DPD Paku skapis / Omniva LV / Latvijas Pasts nodaļa
14.08.2026 {{selectedOffer.parcelStationDeliveryString}}
From 1.79 €
payment
Payment Methods:
Cash payment, Bank transfer, Bank cards on-line, Apple Pay, Google Pay, Leasing for legal entities
Leasing for legal entities: from 47.19 euros per month
Available for private customers at price 1,459.99 €: 2 pcs.
Together cheaper
{{product.price | formatAmount}}
{{product.title}}
{{productBundle.reference.specialPrice | formatAmount}}
{{productBundle.title}}
{{productBundlePreviousPrice | formatAmount}}
{{productBundleSpecialPrice | formatAmount}}

You saving {{productBundleYouSave | formatAmount}}

Product information

Description

APC NetShelter 9000 PDU is a vertical 0U power distribution unit designed for installation inside NetShelter racks and network cabinets. It provides 24 AC outlets in a mixed configuration (C13, C15, C19 and C21) and accepts a NEMA L6-20P input plug for 200–208 V nominal operation at up to 20 A. The unit includes a field-replaceable Network Management Card/Display Module (NMC) to reduce downtime, high-retention outlets for improved cord retention, and hydraulic magnetic circuit breakers for consistent trip performance across temperature variations. This model is certified to CUL, FCC 15 A, IEC 62368-1 and PSE standards.

Advantages

The field-replaceable NMC enables in-situ replacement of the network management module without removing the PDU from service, minimizing disruption. High retention outlets increase plug holding force to reduce accidental disconnects while remaining compatible with standard power cords. Select 9000 series features allow operation at elevated ambient temperatures up to 60°C at full load, supporting high-density deployments. Hydraulic magnetic circuit breakers help maintain reliable overcurrent protection across a wide temperature range.

Suitable for

  • Data center racks and server cabinets requiring mixed outlet types
  • Network closets and telecommunication cabinets with 200–208 V electrical infrastructure
  • High-density equipment deployments where elevated ambient operation is needed
  • Environments needing managed power with remote monitoring and control

Key specifications

  • Form factor: vertical, 0U rack-mount
  • Total outlets: 24 AC outlets (mix of C13, C15, C19, C21 couplers)
  • Input plug type: NEMA L6-20P
  • Nominal voltage: 200–208 V
  • Maximum current: 20 A
  • Network management: field-replaceable Network Management Card/Display Module
  • Outlet retention: high retention design compatible with standard cords
  • Overcurrent protection: hydraulic magnetic circuit breakers
  • Operating temperature capability: select models support up to 60°C at full load
  • Finish: black

How to use

Install the PDU vertically in a compatible NetShelter or 0U-capable rack position and connect the NEMA L6-20P input to an appropriate 200–208 V power source rated for 20 A. Plug equipment into the appropriate outlet types (C13/C15 for lower-power devices, C19/C21 for higher-power devices) ensuring cord compatibility. Use the integrated network management card and display module to configure monitoring, outlet control and alerts; if required, the NMC can be replaced in the field following the manufacturer's service instructions. Verify circuit breaker settings and ensure proper grounding before placing connected equipment into service.

Usage recommendations

Place the PDU in a rack location that allows adequate airflow and access to the NMC. Confirm that attached devices use compatible cords for C13/C15 or C19/C21 outlets, and avoid exceeding the 20 A branch capacity. For installations in higher ambient environments, choose the 9000 series models specified for 60°C operation and follow site electrical codes and thermal management best practices.

Specifications

Maximum current: The greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
20 A
Nominal input voltage: The voltage which the manufacturer recommends that the device needs to operate normally.
200 - 208
AC outlets quantity: The number of sockets in the device where AC electrical power can be connected.
24 AC outlet(s)
Rack capacity: The spase that device fill in rack.
0U
AC outlet types: The type of outlet for AC electricity.
C21 coupler, C19 coupler, C15 coupler, C13 coupler
PDU types: A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP.
Switched
All features

Packaging data

Package height: The distance from the top to the bottom of the packaging.
2002 mm
Package depth: The distance from the front to the back of the packaging.
114 mm
Package width: The distance from one side of the packaging to the other.
165 mm
Package weight: Weight of the packaged product.
7860 g

Weight & dimensions

Weight: Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
5.61 kg
Height: The measurement of the product from head to foot or from base to top.
1797 mm
Depth: The distance from the front to the back of something.
46 mm
Width: The measurement or extent of something from side to side.
55 mm

Operational conditions

Non-operating altitude:
0 - 15240
Operating altitude:
0 - 3048
Operating relative humidity (H-H):
5 - 95
Storage relative humidity (H-H):
5 - 95
Storage temperature (T-T): The minimum and maximum temperatures at which the product can be safely stored.
-25 - 65
Operating temperature (T-T): The minimum and maximum temperatures at which the product can be safely operated.
-5 - 60

Certificates

Certification:
CUL, FCC 15 A, IEC 62368-1, PSE

Power

Load capacity:
3300 VA
Nominal output voltage: The voltage which the manufacturer states that the device can produce.
200 - 208
Maximum current: The greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
20 A
Nominal input voltage: The voltage which the manufacturer recommends that the device needs to operate normally.
200 - 208

Ports & interfaces

AC outlet types: The type of outlet for AC electricity.
C21 coupler, C19 coupler, C15 coupler, C13 coupler
Power plug: A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
NEMA L6-20P
AC outlets quantity: The number of sockets in the device where AC electrical power can be connected.
24 AC outlet(s)

Design

Product colour: The colour e.g. red, blue, green, black, white.
Black
Mounting: What size the mounting head of the product is, to couple it with a camera.
Vertical
Rack capacity: The spase that device fill in rack.
0U
PDU types: A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP.
Switched

Similar products

{{product.title}} Show details Hide details

{{highlightedFeature.featureTitle}}:

{{getProductFeatureValueById(product, highlightedFeature.featureId)}}

{{product.price | formatAmount}}
Might be useful
{{product.manufacturerName}}
{{product.categoryName}}
{{product.title}}
{{product.specialPrice}}
{{product.price}}
Stock data
Warehouse Stock Delivery to the store Store Price
WH354 2 11.08.2026 Best delivery
1,459.99 €
Available only for legal entities
Warehouse Stock Delivery to the store Store Price
EU9 2 11.08.2026 Best delivery
1,355.99 €
WH109 2 25.08.2026
1,458.49 €
1,459.99 €
Stock: 2
Delivery Date: 11.08.2026 Best delivery
Warehouse: WH354
Available only for legal entities
1,355.99 €
Stock: 2
Delivery Date: 11.08.2026 Best delivery
Warehouse: EU9
1,458.49 €
Stock: 2
Delivery Date: 25.08.2026
Warehouse: WH109

Customer reviews

Customer questions

FAQ

How much does the APC NetShelter 9000 PDU 24 AC outlets cost, and is it available for purchase?

The price is 1,355.99 € (valid at the time of publication and already includes all taxes). The item is available for order — 6 pcs. are in stock, and you can place your purchase right now with delivery across Latvia and Europe or choose pickup at the Riga collection point. We offer favorable purchase terms, including the option to split the payment into convenient monthly installments. Availability and price are updated in real time, so we recommend placing your order in advance.

If I order this product today, when will I receive my order?

If you place your order today, delivery will be as fast and convenient as possible. You will be able to pick up your order on 11.08.2026 at the Riga pickup point or choose delivery across Latvia and Europe. We carefully inspect every purchase and pack it securely for safe transportation.

What payment options are available?

AiO.lv offers several payment methods: Cash payment, Bank transfer, Bank cards on-line, Apple Pay, Google Pay, Leasing for legal entities. All transactions are 100% secure and encrypted.

Can this product be purchased for a company (with VAT)?

Yes. AiO.lv works with legal entities in Latvia and across Europe. The product price already includes VAT. For certain product categories, as well as for companies from other EU countries with a valid VAT number, a 0% VAT rate may apply. We issue the invoice immediately after the order is placed, support electronic BIS invoices, and automatically generate all necessary accounting documents. You can complete the purchase for a company online — simply select the company profile and choose bank transfer as the payment method during checkout.

What is the warranty period?

All APC products come with an official 2 Years warranty. It covers all manufacturing defects and malfunctions that may occur during use. The warranty is valid at all authorized APC service centers and through AiO.lv

Can the product be returned after purchase?

Yes, you can return the product within 14 days of purchase if you bought it as a consumer (not a legal entity). Returns are possible without giving any reason — the main condition is that the product retains its original appearance and full set of accessories. We will make the process as simple and convenient as possible: just contact our customer support team, and we will help you arrange the return.

Where should I contact for warranty service?

For warranty-related questions you can contact the AiO.lv (SIA VSPRO) customer support team. We will assist with consultation, warranty claim processing, and coordination with certified service centers.

How can I tell if this product suits my needs?

When making a choice, we recommend paying attention to the key features: maximum current, nominal input voltage, ac outlets quantity, rack capacity, ac outlet types, pdu types, compatibility with your devices or usage conditions, material quality, functionality, and warranty terms. These characteristics will help you determine how well the model meets your needs.

Where can I download the instructions for APC NetShelter 9000 PDU 24 AC outlets?

You can download the instructions in PDF format from the “Instructions” section on the product description page. The file contains complete information about installation, setup, and usage.
warranty
14-Day Return Policy We are confident in our quality, but if the purchase doesn’t fit — you have 14 days to return the product with peace of mind.
shipping
Fast Delivery Get your orders as quickly as possible — right to your door, parcel lockers, or pickup points across Latvia and the EU.
payment
Secure Payment Pay the way you prefer: cash, VISA, MasterCard, Apple Pay, Google Pay, bank transfer, or 0% installment plan.
warranty
Quality Since 2008 AiO.lv has been on the market for over 18 years and has earned trust — with more than 6000 genuine positive reviews on Google.