Uninterruptible Power Supply Eaton 9PX2200IRT3U
The Eaton 9PX2200IRT3U is a double-conversion online uninterruptible power supply designed for rackmount or tower installation. Delivering 2.2 kVA (2200 W) of output power, it protects critical IT equipment from power interruptions, voltage fluctuations and frequency variations. The unit includes 10 AC outlets in C13 and C19 formats, one USB 2.0 port for basic connectivity, and uses sealed lead acid battery technology in a 3U form factor. It is certified to IEC/EN and UL standards and is intended for environments that require reliable, continuous power protection.
The Eaton 9PX2200IRT3U provides online double-conversion topology for consistent voltage and frequency regulation, ensuring a stable sine wave output to connected equipment. Its 3U rack footprint and tower-capable design save space while allowing flexible deployment in server rooms and network closets. With ten AC outlets of mixed C13 and C19 types, the UPS accommodates common server and network device plugs. The integrated USB 2.0 interface supports orderly shutdown and basic monitoring, and sealed lead acid batteries offer established, maintenance-minimized backup power.
Install the Eaton 9PX2200IRT3U in a server rack occupying 3U of space or place it on a stable surface in tower orientation. Connect equipment to the available C13 and C19 AC outlets according to power requirements, ensuring total connected load does not exceed the 2200 W rating. Plug the UPS into a properly rated mains outlet and allow the unit to charge its internal batteries before relying on battery runtime for extended outages. Use the USB 2.0 connection to link to a management station for basic monitoring and orderly shutdown procedures when supported by the software.
Position the UPS in a ventilated area free from excessive dust and heat, and avoid stacking heavy objects on top. Regularly verify battery condition and runtime under expected loads; replace sealed lead acid batteries according to manufacturer guidance or when capacity noticeably declines. For installations with sensitive equipment or complex power management needs, integrate the UPS with appropriate monitoring software and follow Eaton’s installation and safety instructions.
{{highlightedFeature.featureTitle}}:
{{getProductFeatureValueById(product, highlightedFeature.featureId)}}
{{ productComparisonGenerationError }}