LSiS AR-180 Mechanical Interlock for MC-185a to MC-400a Contactors
LSiS AR-180 Mechanical Interlock for MC-185a to MC-400a Contactors
In cart {{totalProductsCount}} item(s)
Your cart is empty
LSiS AR-180 Mechanical Interlock for MC-185a to MC-400a Contactors
Leave your address - as soon as the price of the product goes down, you'll know about it right away
LSiS AR-180 Mechanical Interlock for MC-185a to MC-400a Contactors
LSiS AR-180 Mechanical Interlock for MC-185a to MC-400a Contactors
The LSiS AR-180 mechanical interlock is a precision-engineered accessory designed specifically for LSiS MC-185a through MC-400a series contactors. This device serves as a critical safety component in industrial electrical systems, providing a robust physical barrier that prevents two contactors from closing simultaneously. By ensuring that only one contactor can be engaged at any given time, the AR-180 effectively eliminates the risk of short circuits during motor reversing or power changeover operations.
The primary benefit of the LSiS AR-180 is the enhanced operational safety it brings to complex control circuits. Its mechanical design is highly reliable, offering a fail-safe solution that does not depend on electrical signals or software logic. The installation process is straightforward, allowing for seamless integration with compatible contactor models. By preventing phase-to-phase faults, this interlock significantly extends the lifespan of your electrical equipment and protects the overall integrity of the control panel.
This mechanical interlock is exclusively designed for the LSiS MC-185a to MC-400a contactor range. It is not compatible with contactors from other manufacturers or different series within the LSiS product line. Furthermore, it is intended for mechanical interlocking only and does not provide electrical interlocking functions on its own.
To install the AR-180, ensure that the power supply to the contactors is completely disconnected. Mount the interlock unit between the two contactors according to the provided mechanical alignment points. Ensure that the linkage is securely fastened and that the mechanical movement is smooth and unobstructed. Before applying power, manually test the interlock by attempting to engage both contactors simultaneously to verify that the mechanism prevents both from closing at once.
Regularly inspect the mechanical linkage for signs of wear or debris accumulation to ensure continued reliable operation. Always perform a manual test after any maintenance or adjustment to the contactor assembly.