Leave your address - as soon as the price of the product goes down, you'll know about it right away
LSiS Auxiliary Contact AX for TD/TS 100-800 Circuit Breakers
LSiS Auxiliary Contact AX for TD/TS 100-800 Circuit Breakers
In cart {{totalProductsCount}} item(s)
Your cart is empty
LSiS Auxiliary Contact AX for TD/TS 100-800 Circuit Breakers
Leave your address - as soon as the price of the product goes down, you'll know about it right away
LSiS Auxiliary Contact AX for TD/TS 100-800 Circuit Breakers
LSiS Auxiliary Contact AX for TD/TS 100-800 Circuit Breakers
The LSiS Auxiliary Contact AX is a precision-engineered accessory designed specifically for integration with LSiS TD and TS series molded case circuit breakers, covering a current range from 100A to 800A. This component serves as a critical interface for electrical distribution systems, providing reliable status signaling that allows for effective remote monitoring and control of circuit breaker operations. By delivering accurate feedback on the switching state, it ensures that operators can maintain oversight of electrical infrastructure in real-time.
The primary benefit of the LSiS auxiliary contact is its seamless compatibility with a wide range of molded case circuit breakers, ensuring a standardized approach to system monitoring. Its robust design guarantees consistent performance and high reliability in demanding industrial environments. By facilitating remote status indication, this accessory significantly enhances operational safety and efficiency, allowing for rapid response to switching events without the need for manual inspection of the breaker unit.
This auxiliary contact is exclusively designed for use with specific LSiS TD and TS series molded case circuit breakers. It is not compatible with other brands or different series of circuit breakers. Furthermore, it is not intended for direct power switching or as a primary protection device.
Installation should be performed by a qualified electrician in accordance with local electrical codes and the manufacturer's installation manual. The auxiliary contact is mounted directly into the designated slot within the compatible circuit breaker housing. Once installed, the electrical connections for the signaling circuit must be wired to the appropriate monitoring or control equipment. Ensure that the circuit breaker is de-energized before attempting any installation or maintenance procedures.
Regularly test the signaling function during scheduled maintenance intervals to ensure the continued accuracy of remote status monitoring and to verify the integrity of the electrical connections.
{{highlightedFeature.featureTitle}}:
{{getProductFeatureValueById(product, highlightedFeature.featureId)}}