Leave your address - as soon as the price of the product goes down, you'll know about it right away
Power distribution panel 19" 1U OEM 9612 — 7× 220V IEC C19 16A
Power distribution panel 19" 1U OEM 9612 — 7× 220V IEC C19 16A
In cart {{totalProductsCount}} item(s)
Your cart is empty
Power distribution panel 19" 1U OEM 9612 — 7× 220V IEC C19 16A
Leave your address - as soon as the price of the product goes down, you'll know about it right away
Power distribution panel 19" 1U OEM 9612 — 7× 220V IEC C19 16A
Power distribution panel 19" 1U OEM 9612 — 7× 220V IEC C19 16A
Power distribution panel 19" 1U OEM 9612 — 7× 220V IEC C19 16A is a rack-mountable unit designed to provide consolidated power delivery inside standard 19-inch server racks. The compact 1U height saves space while offering seven IEC C19 outlets rated for 220 V and up to 16 A each. The panel is intended for organized feeding of high-current IT equipment such as rack servers, blade systems and power-hungry networking devices.
The design combines a standardized 19" 1U format with seven IEC C19 sockets to reduce cable clutter and centralize power distribution. Its metal chassis provides mechanical stability in rack environments and facilitates neat horizontal mounting. Each outlet supports 220 V/16 A, enabling connection of multiple high-current devices without requiring separate external power strips. The unit’s straightforward layout simplifies installation and maintenance in data centers and telecommunications rooms.
Install the panel into a standard 19-inch rack occupying one unit of vertical space. Secure the unit with appropriate rack screws and ensure the chassis is properly grounded before connecting equipment. Feed an appropriate mains input cable into the panel according to local electrical codes and the rack’s power distribution plan. Connect IT devices to the IEC C19 outlets, observing the 16 A per-outlet rating to avoid overload. Verify load distribution across outlets and monitor rack power consumption as part of routine maintenance.
Ensure that the panel is installed by qualified personnel and that the mains supply, branch circuits and protective devices match the panel’s rated voltage and current. Avoid exceeding the 16 A rating per outlet and plan device placement to balance loads across the rack. Regularly inspect connectors and cables for wear, and maintain clear access to the panel for safe operation and service.
{{highlightedFeature.featureTitle}}:
{{getProductFeatureValueById(product, highlightedFeature.featureId)}}