Leave your address - as soon as the price of the product goes down, you'll know about it right away
Terminal strip PAWBOL LZ 5×1.5–4 mm² 32 A (E.4003) — 5 poles, screw clamp
Terminal strip PAWBOL LZ 5×1.5–4 mm² 32 A (E.4003) — 5 poles, screw clamp
In cart {{totalProductsCount}} item(s)
Your cart is empty
Terminal strip PAWBOL LZ 5×1.5–4 mm² 32 A (E.4003) — 5 poles, screw clamp
Leave your address - as soon as the price of the product goes down, you'll know about it right away
Terminal strip PAWBOL LZ 5×1.5–4 mm² 32 A (E.4003) — 5 poles, screw clamp
Terminal strip PAWBOL LZ 5×1.5–4 mm² 32 A (E.4003) — 5 poles, screw clamp
PAWBOL LZ 5×1.5–4 mm² 32 A (E.4003) is a five-pole terminal strip with screw-clamp connections designed for linking copper conductors with cross-sections from 1.5 to 4 mm². The connector provides rated current handling up to 32 A and secure mechanical retention for reliable electrical continuity in indoor wiring, distribution blocks, junction boxes and control panels. Its compact, five-connection layout allows organized conductor routing and straightforward assembly in equipment and installation enclosures.
The screw-clamp design ensures a stable electrical contact and simple, tool-accessible tightening. The product supports a range of conductor sizes (1.5–4 mm²), enabling flexible use across different circuit requirements without separate adapters. The five-pole configuration reduces wiring complexity by grouping multiple conductors in a single, compact component suitable for confined installation spaces. Materials and construction provide consistent mechanical retention under normal indoor operating conditions.
Strip the conductor insulation to the recommended length for the terminal, insert the bare conductor into the clamp entry and tighten the screw to secure the conductor. Ensure that the conductor is fully inserted and that the screw is tightened to a firm torque appropriate for the conductor size to achieve reliable contact while avoiding conductor damage. Use the terminal strip in accordance with applicable electrical codes and isolate power before performing any connections.
Verify conductor type and cross-section before installation and keep connections free of corrosion and contaminants. For parallel or multiple conductors in a single pole, consult local wiring regulations and ensure the combined conductor area does not exceed the specified 1.5–4 mm² range. Periodically inspect terminals in service environments and retighten screws if loosening is detected during maintenance, always with power disconnected.
{{highlightedFeature.featureTitle}}:
{{getProductFeatureValueById(product, highlightedFeature.featureId)}}