Schneider Electric GVAE113 Auxiliary Contact, 1NO + 1NC, Front Mounting
Schneider Electric GVAE113 Auxiliary Contact, 1NO + 1NC, Front Mounting
In cart {{totalProductsCount}} item(s)
Your cart is empty
Schneider Electric GVAE113 Auxiliary Contact, 1NO + 1NC, Front Mounting
Leave your address - as soon as the price of the product goes down, you'll know about it right away
Schneider Electric GVAE113 Auxiliary Contact, 1NO + 1NC, Front Mounting
Schneider Electric GVAE113 Auxiliary Contact, 1NO + 1NC, Front Mounting
The Schneider Electric GVAE113 is a high-quality auxiliary contact block designed for seamless integration with motor circuit breakers. This front-mounted component features a 1NO (normally open) and 1NC (normally closed) configuration, providing essential status signaling for industrial control systems. Engineered for reliability, it ensures precise monitoring and operational safety within electrical installations, maintaining the high standards expected from Schneider Electric protection devices.
This auxiliary contact block offers exceptional reliability in monitoring the status of motor circuit breakers. Its front-mounting design allows for quick and efficient installation, saving valuable time during panel assembly. The robust construction ensures long-term performance in demanding industrial environments, while the 1NO and 1NC configuration provides versatile signaling options for various control and automation requirements.
This component is specifically designed for use with compatible Schneider Electric motor circuit breakers. It is not suitable for standalone operation or for use with incompatible circuit protection devices from other manufacturers.
To install the GVAE113, ensure the motor circuit breaker is disconnected from the power supply. Align the auxiliary contact block with the front mounting interface of the circuit breaker and press firmly until it clicks into place. Once secured, connect the control wires to the appropriate terminals according to your wiring diagram. Verify the connection by testing the signaling function before restoring power to the system.
Always ensure that the electrical system is de-energized before installing or servicing the auxiliary contact block to prevent accidental contact with live parts. Regularly inspect the connections to maintain optimal signal integrity.