Schneider Electric GVAN20 Auxiliary Contact Block, 2NO, Side Mounted
Schneider Electric GVAN20 Auxiliary Contact Block, 2NO, Side Mounted
In cart {{totalProductsCount}} item(s)
Your cart is empty
Schneider Electric GVAN20 Auxiliary Contact Block, 2NO, Side Mounted
Leave your address - as soon as the price of the product goes down, you'll know about it right away
Schneider Electric GVAN20 Auxiliary Contact Block, 2NO, Side Mounted
Schneider Electric GVAN20 Auxiliary Contact Block, 2NO, Side Mounted
The Schneider Electric GVAN20 is a side-mounted auxiliary contact block engineered for seamless integration with TeSys GV2 and GV3 motor circuit breakers. This component features 2 normally open (NO) contacts, serving as a critical interface for monitoring the operational status of motor protection systems. Its robust design ensures reliable performance in demanding industrial environments, facilitating precise feedback within electrical control circuits.
The primary advantage of the GVAN20 is its ability to provide real-time status indication of the connected circuit breaker, which is essential for effective system diagnostics and automation. Its side-mounting configuration allows for space-efficient installation, making it an ideal choice for compact control panels where internal space is limited. The high-quality construction from Schneider Electric guarantees long-term durability and consistent electrical connectivity, reducing the need for frequent maintenance.
This auxiliary contact block is specifically designed for use with the TeSys GV2 and GV3 series. It is not compatible with other circuit breaker lines or brands. Furthermore, it is not intended for high-power switching applications, as it is strictly a signaling device for control circuits.
Installation should be performed by a qualified professional. Ensure the motor circuit breaker is disconnected from the power supply before attempting to attach the GVAN20. The block clips onto the side of the compatible circuit breaker unit. Once physically secured, connect the control wires to the terminals according to your specific circuit diagram. Verify the connection by testing the signaling function before putting the system into full operation.
Always ensure that the electrical load connected to the auxiliary contacts does not exceed the rated specifications to prevent damage to the internal components. Regular inspection of the terminal connections is recommended to maintain optimal signal integrity.