Flue pipe with rain cap Almeva LIL Rura z kielichem 125/180 0.5 m
Flue pipe with rain cap Almeva LIL Rura z kielichem 125/180 0.5 m
In cart {{totalProductsCount}} item(s)
Your cart is empty
Flue pipe with rain cap Almeva LIL Rura z kielichem 125/180 0.5 m
Leave your address - as soon as the price of the product goes down, you'll know about it right away
Flue pipe with rain cap Almeva LIL Rura z kielichem 125/180 0.5 m
Flue pipe with rain cap Almeva LIL Rura z kielichem 125/180 0.5 m
The Almeva LIL Rura z kielichem 125/180 0.5 m is a flue pipe section with an integrated rain cap, designed for use in concentric flue systems with 125/180 mm dimensions. This 0.5 meter length provides a compact extension or connection between appliance outlet and the remainder of the flue run while the built-in rain cap helps prevent water ingress and debris entry. The component is intended for venting combustion appliances and routing exhaust gases in residential and light-commercial installations where concentric flue geometry is required.
This flue pipe section combines a short, rigid length with an integrated rain cap to simplify installation and reduce the number of separate parts on site. Its concentric 125/180 sizing ensures compatibility with matching systems and helps maintain proper draft performance. The rain cap reduces the risk of condensation-related issues and blocks falling debris or precipitation from entering the flue, contributing to longer service intervals for downstream components.
Install the pipe section by inserting the appropriate male/female ends into the matching concentric components of the flue system, following the system manufacturer’s assembly sequence and alignment marks. Ensure joints are fully engaged and secured according to the flue system requirements. The built-in rain cap should face outward to shed precipitation; verify that the overall flue slope and clearances meet local regulations and appliance manufacturer instructions. Perform a leak and draft check after installation and before commissioning the appliance.
Use this pipe section only with compatible concentric flue components and in accordance with national installation standards and the appliance manufacturer’s instructions. Regularly inspect external joints and the rain cap for blockage or corrosion; clear any debris to maintain proper exhaust flow and prevent water ingress.