Power Cable elpar N2XH-J 5x10 mm² RE B2ca 0.6/1 kV halogen-free
elpar N2XH-J 5x10 mm² RE B2ca 0.6/1 kV halogen-free is a fixed-installation power cable designed for low-voltage energy distribution and power circuits. The cable features five 10 mm² conductors and insulation/materials formulated to be halogen-free, helping to reduce corrosive and toxic emissions in case of fire. It is supplied in reel (RE) form and carries a B2ca reaction-to-fire classification, making it suitable for applications where improved fire performance and limited smoke generation are required.
This power cable combines a standard 0.6/1 kV voltage rating with five conductors of 10 mm² to support multi-core power distribution in buildings and industrial installations. The halogen-free construction reduces the release of corrosive gases and toxic substances during combustion, which helps protect sensitive equipment and improves occupant safety. The B2ca reaction-to-fire class indicates a higher level of fire performance compared with lower classes, and the reel packaging (RE) simplifies handling and installation over longer runs.
This cable is intended for fixed installation and may not be appropriate for applications that require continuous flexing, frequent movement, or direct burial without protective conduits unless the installation meets local regulations for such use. It is also designed for low-voltage systems up to 0.6/1 kV and is not suitable for medium- or high-voltage applications.
Plan the routing and support points for the fixed installation, respecting local electrical codes and standards. Unwind the reel and cut required lengths, taking care to avoid kinking or mechanical damage to the sheath. Strip conductors to the appropriate length for termination at distribution panels, switches, or equipment terminals and use compatible lugs or connectors rated for 10 mm² conductors. Ensure mechanical protection where the cable is exposed to potential impact or abrasion and maintain recommended separation from heat sources. After installation, verify connections, insulation continuity, and protection device settings before energizing the circuit.
For best results, install elpar N2XH-J 5x10 mm² RE B2ca 0.6/1 kV in fixed, supported runs, protect it from sharp edges and mechanical damage, and follow national wiring rules for conductor derating, grouping, and fire safety. Use appropriate tools and qualified personnel for termination and testing to ensure reliable and code-compliant operation.