Dreame vacuums for fast and efficient cleaning!
In cart {{totalProductsCount}} item(s)
Your cart is empty
Air conditioner outdoor unit Rittal SK 3185.730, cooling 750 W, airflow 750 m³/h, 110–240 V, 50–60 Hz
The Rittal SK 3185.730 outdoor air conditioner unit is engineered for cooling industrial enclosures, control cabinets and outdoor electrical housings. It provides a nominal cooling capacity of 750 W and an airflow rate of 750 m³/h, with a factory thermostat setpoint of 35 °C. The unit accepts a wide supply range of 110–240 V at 50–60 Hz and incorporates hybrid efficiency measures such as speed-regulated components and heat pipe technology to reduce energy consumption.
This outdoor air conditioner combines a compact cooling capacity with a high airflow rating to stabilise internal cabinet temperatures in exposed environments. Energy-saving features reduce operating power compared with traditional compressor-only designs, and the multi-voltage capability enables installation in a variety of sites without additional transformers. The unit’s control interface provides intuitive operation and allows setpoint adjustment for reliable temperature management.
This unit is specified for a nominal cooling capacity of 750 W and is intended for enclosure cooling rather than space conditioning of large rooms. It may not be adequate where much higher cooling capacity or full-room air-conditioning is required. Environments requiring explosion-proof or intrinsically safe equipment should verify compliance separately, as the unit is designed for conventional industrial enclosures.
Install the unit on the enclosure roof or approved mounting surface following manufacturer mounting orientation and clearance requirements. Connect the supply within the 110–240 V, 50–60 Hz range and configure the factory thermostat setpoint as needed using the touch display. Ensure airflow paths and filters are clear and that condensate drainage, if applicable, is managed according to site conditions. Regularly inspect and clean air-inlet filters and heat exchanger surfaces to maintain cooling performance.
Operate the unit within its specified voltage and frequency range, maintain the factory or adjusted thermostat setpoint close to the optimal enclosure temperature (commonly around 35 °C for factory setpoint) and perform scheduled maintenance on filters and heat-exchange surfaces to preserve energy-efficient operation and reliable enclosure cooling.
{{highlightedFeature.featureTitle}}:
{{getProductFeatureValueById(product, highlightedFeature.featureId)}}
{{ productComparisonGenerationError }}