Junction Box for Cookers Simet HAD01 80×80×25 mm, 5-Terminal 6 mm², White
Junction Box for Cookers Simet HAD01 80×80×25 mm, 5-Terminal 6 mm², White
In cart {{totalProductsCount}} item(s)
Your cart is empty
Junction Box for Cookers Simet HAD01 80×80×25 mm, 5-Terminal 6 mm², White
Leave your address - as soon as the price of the product goes down, you'll know about it right away
Junction Box for Cookers Simet HAD01 80×80×25 mm, 5-Terminal 6 mm², White
Junction Box for Cookers Simet HAD01 80×80×25 mm, 5-Terminal 6 mm², White
Simet HAD01 is a compact surface-mounted junction box intended for cooker and appliance electrical connections. With external dimensions of 80×80×25 mm and a white enclosure, the unit provides a neat and protected point for terminating and distributing incoming power cables. The box contains five terminals rated for conductors up to 6 mm², allowing safe connection of live, neutral, earth and additional supply lines in kitchen and utility installations.
The Simet HAD01 junction box combines a small footprint with clear internal organization for multi-core connections. Its white, surface-mount enclosure simplifies installation where recessed boxes are not available, and the five robust terminals accept up to 6 mm² conductors for a range of appliance supply requirements. The sealed plastic housing protects connections from accidental contact and helps keep wiring compact and accessible for maintenance.
Mount the junction box on a flat surface using appropriate screws and wall plugs for the substrate. Feed the incoming supply and appliance cables into the enclosure through the designated entry points or drill suitable knockouts if required. Strip conductor insulation to the recommended length, insert each conductor into the appropriate terminal and tighten the terminal screws to the torque recommended by the terminal manufacturer. Ensure earth, neutral and live conductors are connected according to local wiring regulations and that all connections are secure before closing the cover. After wiring, replace the cover and confirm that the enclosure is fixed and that no bare conductors are exposed.
Use the Simet HAD01 junction box with conductors within the specified 6 mm² limit and follow local electrical codes. For high-current cooker circuits verify terminal suitability and screw torque. Ensure installation is performed by a qualified electrician and isolate power before beginning work.