TT Cables N2XH-J Halogen-Free Power Cable, 3 x 1.5 mm², B2ca, 500m
TT Cables N2XH-J Halogen-Free Power Cable, 3 x 1.5 mm², B2ca, 500m
In cart {{totalProductsCount}} item(s)
Your cart is empty
TT Cables N2XH-J Halogen-Free Power Cable, 3 x 1.5 mm², B2ca, 500m
Leave your address - as soon as the price of the product goes down, you'll know about it right away
TT Cables N2XH-J Halogen-Free Power Cable, 3 x 1.5 mm², B2ca, 500m
TT Cables N2XH-J Halogen-Free Power Cable, 3 x 1.5 mm², B2ca, 500m
The TT Cables N2XH-J is a high-performance halogen-free power cable engineered for fixed installations in environments where fire safety and reliability are paramount. With a construction featuring three conductors of 1.5 mm² cross-section, this cable is designed to provide stable electrical distribution while minimizing risks in the event of a fire. Its B2ca fire classification ensures that the cable produces minimal smoke and no toxic gases, making it a secure choice for modern building infrastructure.
The primary benefit of the TT Cables N2XH-J lies in its advanced halogen-free material composition, which significantly enhances safety standards in enclosed spaces. By preventing the release of corrosive or toxic fumes during combustion, it protects both occupants and sensitive electronic equipment. The robust hose-shaped design facilitates easy routing through conduits and cable trays, while the high-quality insulation ensures long-term durability and consistent electrical performance across various environmental conditions.
This cable may not be suitable for applications requiring high mechanical flexibility or constant movement, as it is specifically designed for fixed installations. It is also not intended for direct burial in the ground without additional protective conduits or for use in environments where it will be exposed to extreme chemical solvents not accounted for in its technical specifications.
The cable should be installed by qualified professionals in accordance with local electrical regulations. It is suitable for mounting on cable trays, in conduits, or directly on walls within dry or damp environments. When stripping the insulation, ensure that the copper conductors remain undamaged to maintain optimal conductivity. Secure the cable using appropriate clips or ties to prevent sagging or mechanical stress on the connection points.
Usage recommendations: Always handle the cable with care during installation to avoid kinking or damaging the outer sheath. Ensure that all connections are tightened to the manufacturer's torque specifications to prevent overheating at termination points.