Leave your address - as soon as the price of the product goes down, you'll know about it right away
TT Cables NHXH-J RE/SP FE180/E90 Power Cable, 3 x 2.5mm², 500m
TT Cables NHXH-J RE/SP FE180/E90 Power Cable, 3 x 2.5mm², 500m
In cart {{totalProductsCount}} item(s)
Your cart is empty
TT Cables NHXH-J RE/SP FE180/E90 Power Cable, 3 x 2.5mm², 500m
Leave your address - as soon as the price of the product goes down, you'll know about it right away
TT Cables NHXH-J RE/SP FE180/E90 Power Cable, 3 x 2.5mm², 500m
TT Cables NHXH-J RE/SP FE180/E90 Power Cable, 3 x 2.5mm², 500m
The TT Cables NHXH-J RE/SP FE180/E90 is a high-performance, halogen-free power cable engineered for critical infrastructure and environments where fire safety is the highest priority. This cable features three conductors with a cross-section of 2.5mm², designed to maintain circuit integrity during fire conditions. With an E90 rating, it ensures power supply for 90 minutes during a fire, while the FE180 insulation integrity rating guarantees operation for 180 minutes, making it a reliable choice for life-safety systems.
This cable offers exceptional fire resistance and safety features, including low smoke emission and the absence of toxic halogen gases in the event of combustion. Its robust construction ensures durability in demanding professional electrical installations. The orange outer sheath allows for easy identification as a fire-resistant cable, while the high-quality materials provide long-term reliability and protection for essential electrical circuits in public and industrial buildings.
This cable may not be suitable for outdoor installations where it is directly exposed to prolonged UV radiation or submerged in water, as it is primarily designed for fixed installations within buildings. It is also not intended for applications requiring high flexibility or constant movement, such as robotic arms or mobile equipment.
The cable should be installed by qualified electrical professionals in accordance with local building codes and fire safety regulations. It is suitable for fixed installation in dry or damp environments, either on, in, or under plaster, as well as in cable ducts. When routing the cable, ensure that the minimum bending radius is respected to prevent damage to the internal conductors and insulation layers. Connections should be made using appropriate fire-rated junction boxes and terminals to maintain the overall integrity of the fire-resistant system.
Always ensure that the cable is installed in compliance with national fire safety standards and electrical installation guidelines. Avoid mechanical stress during installation and ensure that all connections are properly secured to maintain the fire-resistant properties of the circuit.
{{highlightedFeature.featureTitle}}:
{{getProductFeatureValueById(product, highlightedFeature.featureId)}}