Leave your address - as soon as the price of the product goes down, you'll know about it right away
Chimney Condensate Collector WADEX 114 A (114 mm diameter)
Chimney Condensate Collector WADEX 114 A (114 mm diameter)
In cart {{totalProductsCount}} item(s)
Your cart is empty
Chimney Condensate Collector WADEX 114 A (114 mm diameter)
Leave your address - as soon as the price of the product goes down, you'll know about it right away
Chimney Condensate Collector WADEX 114 A (114 mm diameter)
Chimney Condensate Collector WADEX 114 A (114 mm diameter)
The WADEX Chimney Condensate Collector 114 A is made for connection to flue systems with an internal diameter of 114 mm. It collects acidic condensate formed in combustion gases and provides a controlled outlet for safe drainage. The unit is compatible with gas, oil and solid fuel appliances where condensate formation is expected and where accessible installation in the flue allows periodic inspection and maintenance. The design supports condensation management while helping to protect downstream chimney components and drainage runs from acidic attack.
The condensate collector offers a compact, purpose-built solution for capturing and discharging acidic condensate. It is engineered to fit directly into a 114 mm flue run and provides a secure connection point for condensate drainage and inspection. By isolating and controlling condensate flow, the device reduces the risk of corrosion to chimney liners and drainage systems and simplifies maintenance tasks related to condensate removal.
Install the condensate collector in an accessible horizontal or vertical section of the flue with an internal diameter of 114 mm, ensuring secure mechanical connection and correct orientation for condensate flow. Connect a suitable drainage line to the collector outlet and route it to an appropriate drain or condensate neutraliser as required by local regulations. Perform periodic visual inspections and remove any debris or deposits to maintain free drainage. Follow appliance and flue manufacturer guidance for clearance and sealing requirements during installation.
Where condensate is acidic, route the discharge through a condensate neutraliser or corrosion-resistant drainage run and comply with local building and environmental regulations. Ensure the collector remains accessible for inspection and maintenance and check connections regularly for signs of leakage or corrosion.
{{highlightedFeature.featureTitle}}:
{{getProductFeatureValueById(product, highlightedFeature.featureId)}}
| Warehouse | Stock | Delivery to the store | Store Price | |
| WH360 | 23 | 29.06.2026 Best delivery | 11.49 € Best price | |
| WH357 | 23 | 13.07.2026 | 28.99 € |
|
11.49 €
Stock:
23
Delivery Date:
29.06.2026
Best delivery
Warehouse: WH360
|
|
28.99 €
Stock:
23
Delivery Date:
13.07.2026
Warehouse: WH357
|