Leave your address - as soon as the price of the product goes down, you'll know about it right away
Fire alarm cable BITNER YnTKSYekw 1x2x0.8, single pair, 100 m reel
Fire alarm cable BITNER YnTKSYekw 1x2x0.8, single pair, 100 m reel
In cart {{totalProductsCount}} item(s)
Your cart is empty
Fire alarm cable BITNER YnTKSYekw 1x2x0.8, single pair, 100 m reel
Leave your address - as soon as the price of the product goes down, you'll know about it right away
Fire alarm cable BITNER YnTKSYekw 1x2x0.8, single pair, 100 m reel
Fire alarm cable BITNER YnTKSYekw 1x2x0.8, single pair, 100 m reel
BITNER YnTKSYekw 1x2x0.8 fire alarm cable on a 100 m reel is designed for signal connection and transmission in fire detection and alarm systems. The single pair construction with 0.8 mm conductors ensures consistent low-voltage signal continuity for detectors, manual call points and control panels. Supplied on a compact 100 m reel, the cable is suitable for fixed indoor installations where a combination of electrical performance and mechanical protection is required.
The cable offers a purpose-designed conductor size and pair configuration for reliable low-voltage signalling over short to medium runs. Its mechanical sheathing provides protection against abrasion and common installation stresses encountered in building interiors. Delivered on a reel, the product allows for measured unwinding and reduces handling time during installation. The single-pair layout simplifies termination and routing for fire alarm circuits.
Plan the cable route from detectors to the fire alarm control panel, avoiding sources of strong electromagnetic interference and excessive heat. Cut and unspool the required length from the 100 m reel, strip insulation only where necessary for a secure termination. Use appropriate fire alarm connectors or terminal blocks that match the system requirements, and maintain polarity where required by the control equipment. Secure the cable at regular intervals with non-metallic clips or ties designed for low-voltage installations to prevent mechanical strain on terminations.
For reliable system performance, install the cable in accordance with local fire and electrical codes, avoid routing alongside high-voltage power cables, and use separate conduits or segregation where necessary. Test continuity and signal integrity after installation and label runs clearly for future maintenance.
{{highlightedFeature.featureTitle}}:
{{getProductFeatureValueById(product, highlightedFeature.featureId)}}