Alarm/intercom cable BITNER YTDY 10×0.5 mm — 100 m
Alarm/intercom cable BITNER YTDY 10×0.5 mm — 100 m
In cart {{totalProductsCount}} item(s)
Your cart is empty
Alarm/intercom cable BITNER YTDY 10×0.5 mm — 100 m
Leave your address - as soon as the price of the product goes down, you'll know about it right away
Alarm/intercom cable BITNER YTDY 10×0.5 mm — 100 m
Alarm/intercom cable BITNER YTDY 10×0.5 mm — 100 m
BITNER YTDY 10×0.5 mm — 100 m is a multi-core cable engineered for alarm and intercom (domofon) systems. The roll contains ten 0.5 mm² conductors designed for low-voltage signal transmission within indoor fixed wiring. This cable supports multiple separate signal lines for door entry panels, sensors, control modules and alarm panels where several parallel circuits are required in the same sheath.
The construction provides ten individually insulated conductors with consistent 0.5 mm² cross-section, offering stable low-voltage performance and predictable signal behaviour. The single-sheath format simplifies routing and installation in conduits, cable trays and behind panels. Its design minimizes crosstalk between circuits in typical alarm and intercom layouts and is suitable for runs inside buildings where environmental exposure is limited.
Plan conductor assignments according to the system wiring diagram, keeping power, audio and data pairs separated as required by the equipment manufacturer. Strip the outer sheath and individual conductor insulation carefully to avoid nicking the copper. Terminate each conductor on the corresponding terminal block or connector, observing polarity where applicable. Route the cable through conduits or cable channels, secure at regular intervals, and avoid tight bends that can deform the sheath or conductors. For longer runs, verify signal integrity and continuity before completing connections to peripheral devices.
Use this cable for indoor, dry locations and fixed installations only. Avoid exposure to direct sunlight, excessive moisture or mechanical damage. Separate low-voltage signal runs from mains power cables to reduce interference; where crossing is unavoidable, keep crossings at right angles. Follow local electrical codes and the device manufacturers' installation instructions when integrating with alarm or intercom equipment.