Leave your address - as soon as the price of the product goes down, you'll know about it right away
EATON PKM0-6,3 3-Pole Motor Protection Circuit Breaker 6.3A 2.2kW
EATON PKM0-6,3 3-Pole Motor Protection Circuit Breaker 6.3A 2.2kW
In cart {{totalProductsCount}} item(s)
Your cart is empty
EATON PKM0-6,3 3-Pole Motor Protection Circuit Breaker 6.3A 2.2kW
Leave your address - as soon as the price of the product goes down, you'll know about it right away
EATON PKM0-6,3 3-Pole Motor Protection Circuit Breaker 6.3A 2.2kW
EATON PKM0-6,3 3-Pole Motor Protection Circuit Breaker 6.3A 2.2kW
The EATON PKM0-6,3 is a high-performance 3-pole motor protection circuit breaker engineered to provide robust electrical safety for industrial and commercial motor applications. This device is specifically designed to monitor and protect electric motors from the risks of overloads and short circuits, ensuring consistent performance and preventing costly equipment damage. With a compact design and reliable switching mechanism, it serves as a critical component in modern electrical distribution systems.
This motor protection circuit breaker offers exceptional reliability through its precise thermal and magnetic tripping characteristics. By integrating overload and short-circuit protection into a single unit, it simplifies panel design and reduces the space required for installation. The robust construction ensures long-term durability even in demanding environments, while the intuitive design allows for quick and secure integration into existing electrical circuits, providing peace of mind for facility managers and electrical engineers.
This device is not intended for use in circuits exceeding its rated current of 6.3A or power capacity of 2.2kW. It should not be installed in environments with extreme moisture or corrosive gases unless housed in a suitable protective enclosure.
The EATON PKM0-6,3 should be installed by a qualified electrician in accordance with local electrical codes. The device is typically mounted on a standard DIN rail within a control cabinet. Connect the power supply cables to the input terminals and the motor leads to the output terminals, ensuring all connections are tightened to the specified torque. Once installed, the breaker can be manually switched on or off using the front-facing toggle. In the event of a trip, the device must be inspected for faults before being reset.
Always perform a continuity and insulation test on the motor circuit before energizing the breaker for the first time to ensure there are no pre-existing faults in the wiring.
{{highlightedFeature.featureTitle}}:
{{getProductFeatureValueById(product, highlightedFeature.featureId)}}