Eaton PFIM-100/4/03 Residual Current Circuit Breaker, 4-Pole, 100A, 0.3A, Type AC
The Eaton PFIM-100/4/03 is a high-performance 4-pole residual current circuit breaker (RCCB) engineered to provide robust protection against electrical faults in various distribution systems. This device is designed to monitor electrical circuits and automatically disconnect power when a residual current is detected, thereby safeguarding personnel and equipment from potential hazards. With its reliable construction and adherence to international safety standards, it serves as a critical component for maintaining electrical integrity in demanding environments.
This residual current circuit breaker offers exceptional reliability and consistent performance in monitoring electrical circuits. Its 4-pole configuration allows for versatile application in three-phase systems, ensuring comprehensive protection across all phases and the neutral conductor. The device is built to withstand rigorous operational conditions, providing long-term stability and peace of mind for facility managers and electrical installers. By integrating this component into your electrical infrastructure, you ensure a high level of safety and compliance with modern electrical regulations.
This device is a Type AC residual current circuit breaker, which is designed to detect sinusoidal AC residual currents. It may not be suitable for circuits containing electronic equipment that generates DC components or high-frequency currents, as these may interfere with the tripping mechanism. For such applications, a Type A or Type B device would be required.
The Eaton PFIM-100/4/03 must be installed by a qualified electrician in accordance with local electrical codes and safety regulations. It is typically mounted on a standard DIN rail within an electrical distribution board. Ensure that the supply cables are correctly connected to the input terminals and that the load is connected to the output terminals, maintaining proper phase and neutral alignment. After installation, the device should be tested using the integrated test button to verify its mechanical functionality.
Regular testing of the residual current circuit breaker using the built-in test button is recommended at least every six months to ensure the device remains in optimal working condition and continues to provide the intended level of protection.