EATON 189905 3-Pole Motor Protection Circuit Breaker 7.5kW 10-16A
EATON 189905 3-Pole Motor Protection Circuit Breaker 7.5kW 10-16A
In cart {{totalProductsCount}} item(s)
Your cart is empty
EATON 189905 3-Pole Motor Protection Circuit Breaker 7.5kW 10-16A
Leave your address - as soon as the price of the product goes down, you'll know about it right away
EATON 189905 3-Pole Motor Protection Circuit Breaker 7.5kW 10-16A
EATON 189905 3-Pole Motor Protection Circuit Breaker 7.5kW 10-16A
The EATON 189905 is a professional-grade 3-pole motor protection circuit breaker engineered to provide reliable control and comprehensive safety for electric motors. This device is specifically designed to manage power distribution in industrial and commercial environments, ensuring that motor-driven equipment operates within safe electrical parameters. By integrating both short-circuit and overload protection into a single compact unit, it effectively prevents damage to motors caused by excessive current or electrical faults.
This motor protection circuit breaker offers high operational reliability and durability, making it a dependable choice for demanding electrical systems. Its adjustable thermal release range allows for precise calibration to match the specific current requirements of the connected motor, which enhances protection accuracy. The robust construction ensures long-term performance even in challenging environments, while the 3-pole configuration provides balanced protection across all phases of the power supply.
This device is not intended for use in circuits exceeding its specified power rating of 7.5kW or outside the 10-16A current range. It is also not suitable for applications requiring specialized electronic motor management features beyond standard thermal and magnetic protection.
Installation should be performed by a qualified electrician in accordance with local electrical codes. The device is typically mounted on a standard DIN rail within an electrical enclosure. Once mounted, connect the power supply lines to the input terminals and the motor leads to the output terminals. After installation, the thermal release must be adjusted to the rated current of the motor using the dial on the front of the unit. The device can be manually switched on or off using the front-mounted toggle.
Regularly inspect the circuit breaker for signs of wear or heat damage and perform periodic testing of the trip mechanism to ensure continued operational safety.