Circuit breaker 3-pole EATON xPole Home HN-C63/3 C63A 6kA AC (MPN 194897)
Circuit breaker 3-pole EATON xPole Home HN-C63/3 C63A 6kA AC (MPN 194897)
In cart {{totalProductsCount}} item(s)
Your cart is empty
Circuit breaker 3-pole EATON xPole Home HN-C63/3 C63A 6kA AC (MPN 194897)
Leave your address - as soon as the price of the product goes down, you'll know about it right away
Circuit breaker 3-pole EATON xPole Home HN-C63/3 C63A 6kA AC (MPN 194897)
Circuit breaker 3-pole EATON xPole Home HN-C63/3 C63A 6kA AC (MPN 194897)
The EATON xPole Home HN-C63/3 is a three-pole overcurrent circuit breaker designed for residential and light commercial distribution boards. It provides C characteristic tripping with a rated current of 63 A and a short-circuit breaking capacity of 6 kA (AC). The device is intended for protecting three-phase supply circuits from overload and short-circuit conditions and is compatible with standard DIN-rail installations.
The breaker offers a balance of sensitivity and durability through its C tripping characteristic, suitable for circuits with moderate inrush currents. With a 63 A rated current and 6 kA breaking capacity, it ensures reliable interruption of fault currents in typical household and small commercial installations. Its three-pole design allows simultaneous disconnection of all phases, helping to maintain system safety and reduce risk of phase-to-phase faults.
Install the three-pole breaker on a standard DIN-rail inside the distribution board according to applicable electrical regulations. Connect each phase conductor to its respective pole and ensure proper tightening of terminals. Verify the breaker rating matches load and upstream/downstream protective devices. After installation, switch the device on and perform functional checks under no-load conditions before energising the protected circuits. Any wiring, commissioning or maintenance should be performed by a qualified electrician.
Use this breaker where a C characteristic is appropriate — for circuits with moderate inrush currents such as small motors and consumer loads. Confirm coordination with upstream protection and the 6 kA breaking capacity is sufficient for prospective short-circuit currents in the installation. Regular visual inspections and periodic testing following local standards will help maintain reliable protection.