Eaton PF6-40/2/01 Residual Current Circuit Breaker 2P 40A 0.1A Type AC
Eaton PF6-40/2/01 Residual Current Circuit Breaker 2P 40A 0.1A Type AC
In cart {{totalProductsCount}} item(s)
Your cart is empty
Eaton PF6-40/2/01 Residual Current Circuit Breaker 2P 40A 0.1A Type AC
Leave your address - as soon as the price of the product goes down, you'll know about it right away
Eaton PF6-40/2/01 Residual Current Circuit Breaker 2P 40A 0.1A Type AC
Eaton PF6-40/2/01 Residual Current Circuit Breaker 2P 40A 0.1A Type AC
The Eaton PF6-40/2/01 is a high-quality 2-pole residual current circuit breaker (RCCB) engineered to enhance electrical safety in various environments. This device is designed to detect and interrupt electrical circuits when a leakage current to earth is identified, effectively preventing potential hazards such as electric shocks or fire risks caused by insulation faults. With a robust construction and reliable tripping mechanism, it serves as a critical component in modern electrical distribution systems.
This residual current circuit breaker offers superior protection through its precise sensitivity and rapid response time. Its design ensures seamless integration into standard distribution boards, providing a compact yet powerful solution for monitoring electrical leakage. The device is built to withstand standard operational stresses, ensuring long-term durability and consistent performance in both residential and commercial settings. By utilizing AC type sensitivity, it provides a dependable safeguard against common earth fault currents found in standard household and office electrical networks.
This device is not intended for use in circuits where DC components are present, as it is specifically designed for AC type leakage currents. It should not be used as a primary protection device in industrial environments where high-frequency interference or specialized electrical loads require different sensitivity types.
The Eaton PF6-40/2/01 must be installed by a qualified electrician in accordance with local electrical regulations. It is typically mounted on a standard DIN rail within a distribution enclosure. Ensure that the supply cables are securely connected to the input terminals and the load cables to the output terminals, following the wiring diagram provided on the device housing. After installation, the device should be tested using the integrated test button to verify its mechanical tripping function.
Regularly test the residual current circuit breaker using the built-in test button at least every six months to ensure the internal mechanism remains functional and responsive.