Residual current circuit breaker 2-pole 32A Electro Base E-002173107
Residual current circuit breaker 2-pole 32A Electro Base E-002173107
In cart {{totalProductsCount}} item(s)
Your cart is empty
Residual current circuit breaker 2-pole 32A Electro Base E-002173107
Leave your address - as soon as the price of the product goes down, you'll know about it right away
Residual current circuit breaker 2-pole 32A Electro Base E-002173107
Residual current circuit breaker 2-pole 32A Electro Base E-002173107
Residual current circuit breaker 2-pole 32A Electro Base E-002173107 is a 2-pole residual-current device designed for protection of electrical circuits rated up to 32 A. The device detects imbalance between live and neutral conductors and disconnects the circuit when a leakage current exceeds the trip threshold, reducing the risk of electric shock and electrical fires. It is intended for use in residential and light-commercial installations where a compact two-pole RCD is required to provide ground-fault protection for single-phase circuits.
This 2-pole 32 A residual current circuit breaker provides sensitive residual-current detection with a compact design suitable for standard distribution boards. It offers reliable and fast disconnection to limit fault currents and enhance user safety. The device is compatible with typical single-phase wiring schemes and can be integrated alongside other modular protection and switching devices. Its rated current of 32 A makes it appropriate for protecting medium-load circuits while remaining space-efficient in panel installations.
Install the residual current circuit breaker into a suitably rated distribution board on a standard DIN rail, following local electrical codes and safety practices. Connect the incoming live and neutral conductors to the device terminals marked for line input and connect the outgoing conductors to the load side. Ensure that upstream overcurrent protection is coordinated with the 32 A rating of the device. After wiring, verify correct operation by using the device test button (if present) and perform insulation and continuity checks before energizing the circuit.
Carry out installation and maintenance only by a qualified electrician. Periodically test the residual-current function according to local regulations and the manufacturer's test intervals to confirm reliable operation. Do not exceed the rated current and ensure the device is used within compatible ambient temperature and mounting conditions specified for modular distribution equipment.