Leave your address - as soon as the price of the product goes down, you'll know about it right away
Shielded RJ45 connector electro base RJ45F-6-PROFI for CAT6 STP/FTP cables
Shielded RJ45 connector electro base RJ45F-6-PROFI for CAT6 STP/FTP cables
In cart {{totalProductsCount}} item(s)
Your cart is empty
Shielded RJ45 connector electro base RJ45F-6-PROFI for CAT6 STP/FTP cables
Leave your address - as soon as the price of the product goes down, you'll know about it right away
Shielded RJ45 connector electro base RJ45F-6-PROFI for CAT6 STP/FTP cables
Shielded RJ45 connector electro base RJ45F-6-PROFI for CAT6 STP/FTP cables
The electro base RJ45F-6-PROFI shielded RJ45 connector is made for terminating CAT6 STP/FTP cables to reliable 8P8C modular connections. Constructed with a metal shield and contacts designed for shielded twisted-pair installations, this connector supports high-speed Ethernet links while reducing electromagnetic interference. The design allows secure cable clamping and consistent contact pressure for professional network cabling and structured installations in data centers, server rooms and office networks.
The metal shielding lowers susceptibility to crosstalk and external electromagnetic noise, improving signal integrity over the full length of CAT6 STP/FTP runs. Precision contacts provide reliable electrical connection and minimal insertion loss. The connector body and clamping mechanism ensure stable mechanical retention of the cable and shield continuity when properly installed. Its form factor is compatible with standard 8P8C sockets and keystone modules, enabling straightforward integration into existing structured cabling systems.
Prepare the CAT6 STP/FTP cable by trimming the outer jacket and folding back the drain wire and foil shield to expose the insulated conductors to the required length. Arrange conductors according to the chosen wiring standard (T568A or T568B) and insert them fully into the connector until the wire ends reach the contacts. Ensure the cable shield makes contact with the connector housing before locking the clamp. Use an appropriate crimping or termination tool compatible with shielded RJ45 connectors to secure the contacts and clamp, then verify continuity and shield grounding with a network tester.
For optimal performance, maintain proper cable preparation and consistent wire alignment, confirm that the shield is continuous to ground at least at one end of the link, and test each terminated connection for pair integrity and attenuation. Use compatible tools designed for shielded connectors and follow local cabling standards to ensure compliance with installation requirements.
{{highlightedFeature.featureTitle}}:
{{getProductFeatureValueById(product, highlightedFeature.featureId)}}