Leave your address - as soon as the price of the product goes down, you'll know about it right away
Installation kit with L-O-P disconnector 1×16A 5P 400V, Elektromet 971609
Installation kit with L-O-P disconnector 1×16A 5P 400V, Elektromet 971609
In cart {{totalProductsCount}} item(s)
Your cart is empty
Installation kit with L-O-P disconnector 1×16A 5P 400V, Elektromet 971609
Leave your address - as soon as the price of the product goes down, you'll know about it right away
Installation kit with L-O-P disconnector 1×16A 5P 400V, Elektromet 971609
Installation kit with L-O-P disconnector 1×16A 5P 400V, Elektromet 971609
Installation kit with L-O-P disconnector 1×16A 5P 400V from Elektromet provides a compact solution for safe isolation and switching in three-phase electrical systems. The kit is built around a load-open-proof (L-O-P) disconnector with a rated current of 16 A and five poles (including neutral and earth), compatible with standard 400 V three-phase circuits. It includes mounting and connection accessories required for assembly inside distribution boards and small control cabinets, making it appropriate for installations where a clear, certifiable means of disconnection is needed.
The L-O-P disconnector ensures positive isolation under load conditions, reducing the risk of accidental reconnection and supporting safe maintenance procedures. The kit format simplifies installation by supplying matching mechanical and electrical components, which saves time during assembly and helps maintain consistent wiring practices. Designed for three-phase environments, the device supports reliable switching of all conductors simultaneously and is suitable for integration into residential and light-commercial panels.
Install the disconnector assembly in the distribution board or control cabinet following local electrical codes and the manufacturer’s mechanical instructions. Connect all phases, neutral and protective earth to the corresponding terminals, ensuring correct torque and secure conductor termination. Use the disconnector to obtain visible and verifiable isolation before performing maintenance; operate the handle or actuator to open the contacts under no-load or in compliance with applicable procedures. After work is complete, restore connections following safety checks and ensure the enclosure is closed and secured.
Verify compatibility with the existing electrical system voltage and conductor sizes before installation. Ensure installation and maintenance are carried out by a qualified electrician. Regularly inspect terminals for tightness and signs of wear or overheating to maintain dependable operation.
{{highlightedFeature.featureTitle}}:
{{getProductFeatureValueById(product, highlightedFeature.featureId)}}