ELEKTROPLAST NEO Residual Current Circuit Breaker 40A 30mA 4-Pole Type AC
ELEKTROPLAST NEO Residual Current Circuit Breaker 40A 30mA 4-Pole Type AC
In cart {{totalProductsCount}} item(s)
Your cart is empty
ELEKTROPLAST NEO Residual Current Circuit Breaker 40A 30mA 4-Pole Type AC
Leave your address - as soon as the price of the product goes down, you'll know about it right away
ELEKTROPLAST NEO Residual Current Circuit Breaker 40A 30mA 4-Pole Type AC
ELEKTROPLAST NEO Residual Current Circuit Breaker 40A 30mA 4-Pole Type AC
The ELEKTROPLAST NEO residual current circuit breaker is a high-quality 4-pole safety device engineered to protect electrical circuits from leakage currents. Designed for a rated current of 40A and a sensitivity of 30mA, this Type AC RCD serves as a critical component in modern electrical distribution boards, ensuring that power is automatically disconnected in the event of a fault to prevent electrical hazards.
This device offers reliable performance in both residential and commercial environments by providing rapid response times during leakage events. Its robust construction ensures long-term durability and consistent operation under standard electrical loads. By integrating this circuit breaker into your system, you significantly enhance the safety level of your electrical installation, protecting both users and connected equipment from potential short circuits or ground faults.
This device is not intended for use in DC-sensitive applications or circuits where high-frequency components are present, as it is specifically designed as a Type AC RCD. It should not be used in environments exceeding its rated current capacity of 40A or in specialized industrial settings requiring Type A or Type B protection.
Installation must be performed by a qualified electrician in accordance with local electrical regulations. The device is designed for mounting on a standard DIN rail within an electrical distribution cabinet. Ensure that the supply cables are correctly connected to the input terminals and that the load is connected to the output terminals. After installation, the device should be tested using the integrated test button to verify its mechanical and electrical functionality.
Usage recommendations: Regularly test the residual current circuit breaker using the built-in test button at least every six months to ensure the mechanism remains operational and provides continuous protection.