Leave your address - as soon as the price of the product goes down, you'll know about it right away
Erse 130-CH/HSLCH Control Cable, 2 x 0.75 mm², Cca Rated, 500 m
Erse 130-CH/HSLCH Control Cable, 2 x 0.75 mm², Cca Rated, 500 m
In cart {{totalProductsCount}} item(s)
Your cart is empty
Erse 130-CH/HSLCH Control Cable, 2 x 0.75 mm², Cca Rated, 500 m
Leave your address - as soon as the price of the product goes down, you'll know about it right away
Erse 130-CH/HSLCH Control Cable, 2 x 0.75 mm², Cca Rated, 500 m
Erse 130-CH/HSLCH Control Cable, 2 x 0.75 mm², Cca Rated, 500 m
The Erse 130-CH/HSLCH control cable is a high-performance solution engineered for secure and reliable signal transmission within industrial environments and building automation systems. This cable features a robust construction with two conductors, each with a cross-section of 0.75 mm², and is protected by aluminum shielding to minimize electromagnetic interference. Designed for safety and durability, it meets the Cca fire safety rating, making it a suitable choice for installations in public buildings where stringent fire protection standards are required.
The primary advantage of this cable lies in its halogen-free composition, which significantly reduces the emission of toxic smoke and corrosive gases in the event of a fire. The inclusion of aluminum shielding provides excellent protection against external electrical noise, ensuring signal integrity in complex industrial setups. With its Cca fire rating, the cable offers an elevated level of safety for fixed installations, while the 500-meter reel length provides sufficient material for large-scale projects, reducing the need for frequent splices and connections.
This cable is not intended for applications requiring high mechanical flexibility or constant movement, such as in robotic arms or drag chains, as it is designed specifically for fixed installations. Additionally, it should not be used in environments where the chemical exposure exceeds the specifications of the cable jacket material.
The cable should be installed by qualified personnel in accordance with local electrical regulations. When routing the cable, ensure that the minimum bending radius is respected to avoid damaging the internal conductors or the shielding layer. The cable is designed for fixed installation and should be secured using appropriate cable ties or conduits to prevent mechanical stress. Ensure that the shielding is properly grounded at the termination points to effectively mitigate electromagnetic interference.
For optimal performance and safety, always ensure that the cable is protected from direct sunlight and extreme environmental conditions. Regularly inspect termination points to ensure that the shielding remains intact and properly connected to the grounding system.
{{highlightedFeature.featureTitle}}:
{{getProductFeatureValueById(product, highlightedFeature.featureId)}}