Pressure differential bypass valve Herz model 4004 DN15
Pressure differential bypass valve Herz model 4004 DN15
In cart {{totalProductsCount}} item(s)
Your cart is empty
Pressure differential bypass valve Herz model 4004 DN15
Leave your address - as soon as the price of the product goes down, you'll know about it right away
Pressure differential bypass valve Herz model 4004 DN15
Pressure differential bypass valve Herz model 4004 DN15
The Pressure differential bypass valve Herz model 4004 DN15 is designed to maintain stable differential pressure in hydronic heating and cooling systems by automatically diverting excess flow when pressure differentials exceed set thresholds. The compact DN15 size is suitable for small to medium installations and supports continuous, reliable operation of pumps and control valves. The valve construction is intended to reduce water-borne noise, prevent system imbalance and limit wear on circulating pumps and regulating components.
This bypass valve provides automatic pressure regulation to protect pumps and sensitive control valves from excessive differential pressure. Its compact DN15 form factor allows installation in tight spaces while ensuring consistent hydraulic performance. The model 4004 reduces hydraulic noise and minimizes the risk of valve hunting and oscillation in closed-loop systems. Its mechanical design enables stable operation without electrical power, reducing complexity and maintenance needs.
Install the Herz model 4004 DN15 in parallel to the control valve or in the return line according to hydraulic design to provide a bypass path when differential pressure rises. Ensure the valve orientation and threaded connections match the system piping and use appropriate sealing materials. Commissioning requires verification of differential pressure set point and observing system behaviour during normal and peak flow conditions. No electrical supply is required; adjust and test hydraulically during system start-up.
Place the valve close to the pump or control station to ensure effective pressure stabilization. During commissioning, monitor for proper bypass activation and verify that the valve reduces noise and prevents pump overload. Periodic visual inspection and flushing during scheduled maintenance are advised to avoid debris accumulation; follow local regulations and Herz installation guidelines for best results.