Kanlux 1P B 16A 23140 is a single-pole overcurrent circuit breaker designed to protect electrical circuits from overloads and short circuits. With a B-type tripping characteristic and a rated current of 16 A, this compact device is intended for DIN-rail mounting in residential and light commercial distribution boards. The breaker provides manual switching and automatic disconnection when current exceeds safe limits, ensuring basic circuit protection in compact installations.
The single-pole design occupies minimal space in distribution boards while delivering reliable overcurrent protection for phase conductors. B-type tripping ensures fast response to moderate short-circuit currents typical for residential and light commercial wiring. Manual on/off operation allows simple control and testing, and the DIN-rail form factor simplifies installation and replacement in standard enclosures. The device is suitable where economical, standard overcurrent protection is required.
Install the breaker on a standard DIN-rail inside the distribution board following applicable electrical standards and local regulations. Connect the phase conductor to the breaker input terminal and the load to the output terminal, ensuring secure terminations and correct torque on terminal screws. Use the manual lever to switch the circuit on or off during installation and testing. In case of tripping, identify and rectify the fault condition before resetting the breaker to the ON position.
Use this breaker in circuits where a B-type characteristic and 16 A rated current match the expected load profile. Verify compatibility with the overall installation, ensure correct coordination with upstream and downstream protective devices, and follow local wiring regulations. Regularly inspect connections and test operation after installation or maintenance.