Residual Current Circuit Breaker 4P 100A AC Kanlux 23197
Residual Current Circuit Breaker 4P 100A AC Kanlux 23197
In cart {{totalProductsCount}} item(s)
Your cart is empty
Residual Current Circuit Breaker 4P 100A AC Kanlux 23197
Leave your address - as soon as the price of the product goes down, you'll know about it right away
Residual Current Circuit Breaker 4P 100A AC Kanlux 23197
Residual Current Circuit Breaker 4P 100A AC Kanlux 23197
Kanlux Residual Current Circuit Breaker 4P 100A AC is a 4-pole residual current device designed to detect alternating earth leakage and rapidly disconnect supply in three-phase installations with neutral. The unit rated for 100 A continuous current provides protection against AC-type leakage currents, improving electrical safety in residential and light-commercial distribution boards. The compact housing fits standard panel mounting and is intended for use where selective disconnection of all live conductors and neutral is required to isolate a circuit following a leakage fault.
This 4-pole RCCB offers consistent leakage detection for AC-type faults and ensures simultaneous disconnection of all phases and neutral, reducing the risk of touch voltage on equipment. With a 100 A current rating, it supports higher load circuits commonly found in small commercial and larger residential installations. The device is built to integrate with standard distribution board layouts and provides straightforward electrical safety compliance where earth leakage protection is mandated.
Install the device in the distribution board according to local electrical regulations and wiring practices. Connect the three phase conductors and neutral to the corresponding terminals and ensure tight, secure connections. The RCCB must be placed downstream of the main overcurrent protection where coordinated protection is required. Test the device after installation using the built-in test function or an appropriate testing instrument to verify trip operation and correct wiring before placing the circuit into regular service.
Use this AC-type residual current breaker in installations where alternating leakage currents are expected; avoid use where pulsating DC or high-frequency leakage can occur unless a more suitable residual current type is specified. Periodically test the trip function and inspect terminal tightness as part of routine electrical maintenance to maintain reliable protection.