Switch-disconnector fuse 63A 3-pole Kanlux KSF02-63-3P (23343)
Leave your address - as soon as the price of the product goes down, you'll know about it right away
Switch-disconnector fuse 63A 3-pole Kanlux KSF02-63-3P (23343)
Switch-disconnector fuse 63A 3-pole Kanlux KSF02-63-3P (23343)
Kanlux KSF02-63-3P is a 3-pole switch-disconnector fuse rated at 63 A, intended for safe manual isolation and overcurrent protection in three-phase electrical circuits. Built for installation in distribution boards and switchgear, it provides a visible disconnection point and accepts replaceable cartridge fuses to enable quick fault clearing and maintenance without altering the wiring layout.
The switch-disconnector offers clear mechanical isolation for three poles with a 63 A current rating, combining disconnection and fuse protection in a single compact device. Its design supports routine maintenance and rapid replacement of cartridge fuses, and it is suitable for mounting in standard panel locations. The unit contributes to safer service operations by providing a distinct ON/OFF position and an accessible fuse carrier.
This switch-disconnector is designed for manual operation and 63 A-rated circuits; it is not suitable where higher continuous currents or remote/automatic switching are required. It also requires compatible cartridge fuses of the correct type and rating—without the correct fuses installed the device cannot provide proper overcurrent protection.
Install the device in the distribution board following local electrical regulations and ensure correct tightening of terminals for reliable contact. Fit appropriate cartridge fuses that match the required breaking capacity and characteristic for the protected circuit. Operate the handle to isolate the circuit during maintenance, and replace blown fuses only after locating and remedying the fault. Always switch off upstream supply and confirm absence of voltage before servicing.
Use the switch-disconnector for manual isolation in three-phase circuits where visible and reliable disconnection is required. Pair it with cartridge fuses selected to match the load characteristics and fault current levels, and schedule regular visual inspections to confirm tight connections and proper operation.