Noark single-pole circuit breaker model 100274 B 6A is a compact protective device for 230 V AC electrical installations. It provides overcurrent and short-circuit protection with a B-type tripping characteristic and a rated current of 6 A. The breaker has a breaking capacity of 10 kA and is intended for DIN-rail mounting in standard residential and light-commercial distribution panels. The housing is finished in grey and the device is designed for indoor use with IP20 protection.
This Noark circuit breaker combines a slim DIN-rail form factor with a clear B characteristic suitable for protecting circuits with mainly resistive loads and small inductive components. The device delivers a 10 kA breaking capacity, ensuring safe interruption of short-circuit currents up to that level. Its 1-pole design simplifies installation in single-phase circuits and the IP20 enclosure meets common panel protection requirements.
Install the circuit breaker on a standard DIN rail inside an appropriate distribution board according to local wiring regulations. Connect the phase conductor to the input terminal and the load conductor to the output terminal, ensuring tight and secure terminations. Use the breaker as the protective device for a single-phase branch circuit rated at up to 6 A. Verify correct operation by switching the breaker on and off after installation and perform insulation and continuity checks before energizing the circuit.
Choose this 6 A B-characteristic breaker where inrush currents are low and sensitive tripping for overload protection is required. Confirm that downstream load does not exceed the rated current and that the distribution board provides adequate space and ventilation. Follow national electrical codes for earthing, conductor sizing and protective coordination to ensure reliable protection.