Residual current circuit breaker Noark EX9NLE 111148 with overcurrent protection 1P 30mA type AC EL 1PN B16
Noark EX9NLE 111148 is a single-pole residual current circuit breaker with integrated overcurrent protection (RCBO). It provides earth-fault detection with a rated residual operating current of 30 mA and AC-type sensitivity designed for sinusoidal alternating current leakage. The built-in overcurrent trip uses a B-characteristic at 16 A, combining short-circuit and overload protection with residual current protection in one compact module suitable for residential and light-commercial electrical installations.
The device combines residual-current detection and overcurrent protection in a single unit, reducing the required panel space and simplifying wiring. AC-type sensitivity ensures reliable detection of sinusoidal leakage currents while the 30 mA threshold provides protection against electric shock. The B16 overcurrent characteristic offers prompt tripping for short-circuit and moderate overloads common in lighting and outlet circuits. The single-pole format supports typical single-phase distribution boards and allows easy integration into existing systems.
This device is intended for AC-type leakage detection and will not provide selective detection of pulsating DC or complex residual currents that require A- or F-type sensitivity. For three-phase systems, three-pole or four-pole devices are required instead of this single-pole model. Additionally, applications that require adjustable trip curves or higher continuous current ratings than 16 A should consider alternative devices with appropriate characteristics.
Install the RCBO into a compatible DIN-rail distribution board following local electrical codes. Connect the phase conductor through the device and ensure the neutral and earth conductors are correctly routed according to the installation manual. Verify correct polarity and tightness of terminal connections. After installation, perform standard commissioning tests: measure continuity of protective conductors, verify correct tripping at residual current test points, and confirm overcurrent protection operates within expected parameters during functional testing. Regularly test the residual-current function according to applicable regulations and maintenance schedules.
Use this RCBO on single-phase circuits where combined earth-fault and overcurrent protection is desired and where leakage currents are expected to be sinusoidal. Periodic testing of the residual-current trip and adherence to installation torque and wiring standards will help maintain reliable protection.